Effective integration between daylight and electric light is of paramount importance for high-quality lighting. Currently, daylight-linked control systems are calibrated to guarantee required work-plane illuminance while saving energy, but how can they be calibrated if integrative lighting purposes must be fulfilled? Based on on-field measurements, the functioning of a closed-loop proportional system is simulated considering 3 electric light CCTs and by adopting 4 different calibration strategies: 1 to achieve work-plane illuminance equal to 500 lx and 3 to guarantee melanopic equivalent daylight illuminance (melEDI) equal to 250 lx. Results show that if the system is calibrated to provide adequate work-plane illuminance, sufficient melEDI values are achieved with 6500 K only; if the system is calibrated to achieve melEDI=250 lx, very high work-plane illuminance levels occur in some cases depending on the adopted strategy. Overall, the choice of CCT is crucial to guarantee the simultaneous fulfilment of visual and circadian needs.
Closed-loop proportional daylight-linked control systems: How to calibrate them for integrative lighting purposes? / Bellia, L., Diglio, F., Fragliasso, F.. - (2025), pp. 88-94. (CIE 2025 Midterm Meeting Vienna, Austria July 7-9, 2025) [10.25039/x051.2025/3wcf2g].
Closed-loop proportional daylight-linked control systems: How to calibrate them for integrative lighting purposes?
Laura Bellia;Francesca Diglio;Francesca Fragliasso
2025
Abstract
Effective integration between daylight and electric light is of paramount importance for high-quality lighting. Currently, daylight-linked control systems are calibrated to guarantee required work-plane illuminance while saving energy, but how can they be calibrated if integrative lighting purposes must be fulfilled? Based on on-field measurements, the functioning of a closed-loop proportional system is simulated considering 3 electric light CCTs and by adopting 4 different calibration strategies: 1 to achieve work-plane illuminance equal to 500 lx and 3 to guarantee melanopic equivalent daylight illuminance (melEDI) equal to 250 lx. Results show that if the system is calibrated to provide adequate work-plane illuminance, sufficient melEDI values are achieved with 6500 K only; if the system is calibrated to achieve melEDI=250 lx, very high work-plane illuminance levels occur in some cases depending on the adopted strategy. Overall, the choice of CCT is crucial to guarantee the simultaneous fulfilment of visual and circadian needs.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.