The present paper is dedicated to the evaluation of the influence played by important design parameters like the interturn insulation thickness and the insulating material permittivity on the voltage distribution among the coils of a stator winding fed by a PWM inverter. The system, composed of a feeder cable and a stator winding is modeled and simulated by using multiconductor transmission line theory. A recently developed time-domain equivalent circuit is used to represent the multiconductor line, with losses possibly dependent on frequency, which allows to correctly describe the dielectric losses and the skin-effect in the conductors. The obtained results can offer a broad guideline to design engineers for a suitable dimensioning of the motor insulation.

Influence of coil parameters on the voltage distribution in a machine stator winding fed by a PWM inverter / Petrarca, Carlo; Lupo', Giovanni; V., Tucci; M., Vitelli. - STAMPA. - (2000), pp. 490-493. (Intervento presentato al convegno Conference on Electrical Insulation and Dielectric Phenomena (CEIDP) tenutosi a Victori, BC, Canada nel 15 October 2000 through 18 October 2000).

Influence of coil parameters on the voltage distribution in a machine stator winding fed by a PWM inverter

PETRARCA, CARLO;LUPO', GIOVANNI;
2000

Abstract

The present paper is dedicated to the evaluation of the influence played by important design parameters like the interturn insulation thickness and the insulating material permittivity on the voltage distribution among the coils of a stator winding fed by a PWM inverter. The system, composed of a feeder cable and a stator winding is modeled and simulated by using multiconductor transmission line theory. A recently developed time-domain equivalent circuit is used to represent the multiconductor line, with losses possibly dependent on frequency, which allows to correctly describe the dielectric losses and the skin-effect in the conductors. The obtained results can offer a broad guideline to design engineers for a suitable dimensioning of the motor insulation.
2000
0780364139
Influence of coil parameters on the voltage distribution in a machine stator winding fed by a PWM inverter / Petrarca, Carlo; Lupo', Giovanni; V., Tucci; M., Vitelli. - STAMPA. - (2000), pp. 490-493. (Intervento presentato al convegno Conference on Electrical Insulation and Dielectric Phenomena (CEIDP) tenutosi a Victori, BC, Canada nel 15 October 2000 through 18 October 2000).
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/565875
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 3
social impact