Foetal heart rate variability is considered an important parameter, capable to highlight foetal reactivity and wellbeing. Many studies focused their attention on foetal heart rate variability analysis, using different techniques both in time and frequency domain. Proposed parameters have shown some limitations, due to their inability to analyze nonlinear dynamics, involved in heart rate control and relevant for clinical aims. In the last decades, nonlinear analysis methods have gained a growing interest. Here, we described an application of a nonlinear analysis (symbolic dynamic analysis) and introduced a new index to quantify foetal heart rate variability, in a simple and concise way, in healthy foetuses near to term. The index was able to highlight differences in foetal heart rate variability, not always so evident on printed cardiotocographic signals, and resulted significantly correlated with the different kinds of delivery (spontaneous or caesarean); in particular, higher variability index values corresponded to spontaneous delivery

Symbolic dynamics in cardiotocographic monitoring / Romano, Maria; Bifulco, Paolo; Improta, Giovanni; Faiella, Giuliana; Cesarelli, Mario; Fabrizio, Clemente; D'Addio, Giovanni. - (2013), pp. 1-4. (Intervento presentato al convegno 2013 E-Health and Bioengineering Conference (EHB), 4th IEEE International Conference on E-Health and Bioengineering, EHB 2013; tenutosi a Iasi; Romania nel 21-23 November 2013) [10.1109/EHB.2013.6707374].

Symbolic dynamics in cardiotocographic monitoring

ROMANO, MARIA;BIFULCO, PAOLO;IMPROTA, Giovanni;FAIELLA, GIULIANA;CESARELLI, MARIO;D'ADDIO, Giovanni
2013

Abstract

Foetal heart rate variability is considered an important parameter, capable to highlight foetal reactivity and wellbeing. Many studies focused their attention on foetal heart rate variability analysis, using different techniques both in time and frequency domain. Proposed parameters have shown some limitations, due to their inability to analyze nonlinear dynamics, involved in heart rate control and relevant for clinical aims. In the last decades, nonlinear analysis methods have gained a growing interest. Here, we described an application of a nonlinear analysis (symbolic dynamic analysis) and introduced a new index to quantify foetal heart rate variability, in a simple and concise way, in healthy foetuses near to term. The index was able to highlight differences in foetal heart rate variability, not always so evident on printed cardiotocographic signals, and resulted significantly correlated with the different kinds of delivery (spontaneous or caesarean); in particular, higher variability index values corresponded to spontaneous delivery
2013
9781479923724
9781479923731
Symbolic dynamics in cardiotocographic monitoring / Romano, Maria; Bifulco, Paolo; Improta, Giovanni; Faiella, Giuliana; Cesarelli, Mario; Fabrizio, Clemente; D'Addio, Giovanni. - (2013), pp. 1-4. (Intervento presentato al convegno 2013 E-Health and Bioengineering Conference (EHB), 4th IEEE International Conference on E-Health and Bioengineering, EHB 2013; tenutosi a Iasi; Romania nel 21-23 November 2013) [10.1109/EHB.2013.6707374].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/595528
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 4
social impact