Many cervical spine pathologies involve degeneration of the stabilizing mechanisms of vertebrae segments and often cause pain. Abnormal intervertebral motion is an indication for surgery. Currently, spinal fusion surgery is widely adopted to fix the instable vertebral segments but recently, disk arthroplasty is more and more adopted as an alternative to restore normal kinematics and biomechanics of the sick segment and to reduce development of symptomatic adjacent-level degeneration. This study aims to measure intervertebral kinematics by means of image processing of X-ray fluoroscopy videos, which are able to screen patient's neck spontaneous movements of flexion-extension. Vertebrae trajectories are estimated by using image template matching techniques. Then, continuous-time intervertebral kinematics is computed by using spline interpolation. The results, obtained by using real fluoroscopy videos, reveal the possibility of obtaining in vivo information about the continuous evolution of motion of the implanted prosthesis and adjacent segments

Assessment of cervical disk prosthesis by means of video-fluoroscopy image processing / Bifulco, P.; Iuppariello, L.; Romano, M.; Fratini, A.; Esposito, D.; Clemente, F.; Cesarelli, M.. - (2017), pp. 169-172. (Intervento presentato al convegno 6th IEEE International Conference on E-Health and Bioengineering, EHB 2017 tenutosi a Grigore T. Popa University of Medicine and Pharmacy, rou nel 22-24 June 2017) [10.1109/EHB.2017.7995388].

Assessment of cervical disk prosthesis by means of video-fluoroscopy image processing

Bifulco, P.
;
Iuppariello, L.;Romano, M.;Esposito, D.;Clemente, F.;Cesarelli, M.
2017

Abstract

Many cervical spine pathologies involve degeneration of the stabilizing mechanisms of vertebrae segments and often cause pain. Abnormal intervertebral motion is an indication for surgery. Currently, spinal fusion surgery is widely adopted to fix the instable vertebral segments but recently, disk arthroplasty is more and more adopted as an alternative to restore normal kinematics and biomechanics of the sick segment and to reduce development of symptomatic adjacent-level degeneration. This study aims to measure intervertebral kinematics by means of image processing of X-ray fluoroscopy videos, which are able to screen patient's neck spontaneous movements of flexion-extension. Vertebrae trajectories are estimated by using image template matching techniques. Then, continuous-time intervertebral kinematics is computed by using spline interpolation. The results, obtained by using real fluoroscopy videos, reveal the possibility of obtaining in vivo information about the continuous evolution of motion of the implanted prosthesis and adjacent segments
2017
9781538603581
Assessment of cervical disk prosthesis by means of video-fluoroscopy image processing / Bifulco, P.; Iuppariello, L.; Romano, M.; Fratini, A.; Esposito, D.; Clemente, F.; Cesarelli, M.. - (2017), pp. 169-172. (Intervento presentato al convegno 6th IEEE International Conference on E-Health and Bioengineering, EHB 2017 tenutosi a Grigore T. Popa University of Medicine and Pharmacy, rou nel 22-24 June 2017) [10.1109/EHB.2017.7995388].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/705786
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 1
social impact