This paper presents a sensorless control for a Doubly Fed Induction Generator (DFIG) in the context of grid-connected turbine-based wind generation systems. The paper proposes a full order adaptive observer able to track with excellent accuracy the DFIG rotor position even in presence of significant parameters deviations. The developed adaptive observer is coupled with a traditional stator flux based Field Oriented Control (FOC). The novel approach has been validated by an extensive numerical analysis.
A Full Order Sensorless Control Adaptive Observer for Doubly-Fed Induction Generator / Dannier, Adolfo; Brando, Gianluca; Spina, Ivan. - (2019), pp. 464-469. (Intervento presentato al convegno ICCEP tenutosi a Otranto, Italia) [10.1109/ICCEP.2019.8890195].
A Full Order Sensorless Control Adaptive Observer for Doubly-Fed Induction Generator
Dannier Adolfo
;Gianluca Brando;Ivan Spina
2019
Abstract
This paper presents a sensorless control for a Doubly Fed Induction Generator (DFIG) in the context of grid-connected turbine-based wind generation systems. The paper proposes a full order adaptive observer able to track with excellent accuracy the DFIG rotor position even in presence of significant parameters deviations. The developed adaptive observer is coupled with a traditional stator flux based Field Oriented Control (FOC). The novel approach has been validated by an extensive numerical analysis.File | Dimensione | Formato | |
---|---|---|---|
08890195.pdf
accesso aperto
Descrizione: Articolo principale
Tipologia:
Documento in Post-print
Licenza:
Dominio pubblico
Dimensione
1.22 MB
Formato
Adobe PDF
|
1.22 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.