Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS
The DarkSide-50 experiment, located at the “Laboratori Nazionali del Gran Sasso (INFN)”, is based on low-radioactivity argon double phase time projection chamber, surrounded by an active liquid scintillator veto, designed for the zero background achievement. The liquid argon features sufficient self shielding and easy scalability to multi-tons scale. The impressive reduction of the 39Ar isotope (compared to the atmospheric argon), along with the excellent pulse shape discrimination, make this technology a possible candidate for the forthcoming generation of multi-ton Dark Matter experiments.
The darkside-50 experiment: A liquid argon target for dark matter particles / Agnes, P.; Agostino, L.; Albuquerque, I. F. M.; Alexander, T.; Alton, A. K.; Arisaka, K.; Back, H. O.; Baldin, B.; Biery, K.; Bonfini, G.; Bossa, M.; Bottino, B.; Brigatti, A.; Brodsky, J.; Budano, F.; Bussino, S.; Cadeddu, M.; Cadonati, L.; Cadoni, M.; Calaprice, F.; Canci, N.; Candela, A.; Cao, H.; Cariello, M.; Carlini, M.; Catalanotti, S.; Cavalcante, P.; Chepurnov, A.; Cocco, A. G.; Covone, G.; Crippa, L.; D'Angelo, D.; D'Incecco, M.; Davini, S.; de Cecco, S.; de Deo, M.; de Vincenzi, M.; Derbin, A.; Devoto, A.; di Eusanio, F.; di Pietro, G.; Edkins, E.; Empl, A.; Fan, A.; Fiorillo, G.; Fomenko, K.; Forster, G.; Franco, D.; Gabriele, F.; Galbiati, C.; Giganti, C.; Goretti, A. M.; Granato, F.; Grandi, L.; Gromov, M.; Guan, M.; Guardincerri, Y.; Hackett, B. R.; Herner, K.; Hungerford, E. V.; Ianni, A.; Ianni, A.; James, I.; Jollet, C.; Keeter, K.; Kendziora, C. L.; Kobychev, V.; Koh, G.; Korablev, D.; Korga, G.; Kubankin, A.; Li, X.; Lissia, M.; Lombardi, P.; Luitz, S.; Ma, Y.; Machulin, I. N.; Mandarano, A.; Mari, S. M.; Maricic, J.; Marini, L.; Martoff, C. J.; Meregaglia, A.; Meyers, P. D.; Miletic, T.; Milincic, R.; Montanari, D.; Monte, A.; Montuschi, M.; Monzani, M.; Mosteiro, P.; Mount, B. J.; Muratova, V. N.; Musico, P.; Napolitano, J.; Nelson, A.; Odrowski, S.; Orsini, M.; Ortica, F.; Pagani, L.; Pallavicini, M.; Pantic, E.; Parmeggiano, S.; Pelczar, K.; Pelliccia, N.; Perasso, S.; Pocar, A.; Pordes, S.; Pugachev, D. A.; Qian, H.; Randle, K.; Ranucci, G.; Razeto, A.; Reinhold, B.; Renshaw, A. L.; Romani, A.; Rossi, B.; Rossi, N.; Rountree, D.; Sablone, D.; Saggese, P.; Saldanha, R.; Sands, W.; Sangiorgio, S.; Savarese, C.; Segreto, E.; Semenov, D. A.; Shields, E.; Singh, P. N.; Skorokhvatov, M. D.; Smirnov, O.; Sotnikov, A.; Stanford, C.; Suvorov, Y.; Tartaglia, R.; Tatarowicz, J.; Testera, G.; Tonazzo, A.; Trinchese, P.; Unzhakov, E. V.; Vishneva, A.; Vogelaar, B.; Wada, M.; Walker, S.; Wang, H.; Wang, Y.; Watson, A. W.; Westerdale, S.; Wilhelmi, J.; Wojcik, M. M.; Xiang, X.; Xu, J.; Yang, C.; Yoo, J.; Zavatarelli, S.; Zec, A.; Zhong, W.; Zhu, C.; Zuzel, G.. - 0:211889(2017), pp. 355-360. (Intervento presentato al convegno 17th Lomonosov Conference on Elementary Particle Physics, 2015 tenutosi a rus nel 2015) [10.1142/9789813224568_0057].
The darkside-50 experiment: A liquid argon target for dark matter particles
Agnes P.;Agostino L.;Albuquerque I. F. M.;Alexander T.;Alton A. K.;Arisaka K.;Back H. O.;Baldin B.;Biery K.;Bonfini G.;Bossa M.;Bottino B.;Brigatti A.;Brodsky J.;Budano F.;Bussino S.;Cadeddu M.;Cadonati L.;Cadoni M.;Calaprice F.;Canci N.;Candela A.;Cao H.;Cariello M.;Carlini M.;Catalanotti S.;Cavalcante P.;Chepurnov A.;Cocco A. G.;Covone G.;Crippa L.;D'Angelo D.;D'Incecco M.;Davini S.;de Cecco S.;de Deo M.;de Vincenzi M.;Derbin A.;Devoto A.;di Eusanio F.;di Pietro G.;Edkins E.;Empl A.;Fan A.;Fiorillo G.;Fomenko K.;Forster G.;Franco D.;Gabriele F.;Galbiati C.;Giganti C.;Goretti A. M.;Granato F.;Grandi L.;Gromov M.;Guan M.;Guardincerri Y.;Hackett B. R.;Herner K.;Hungerford E. V.;Ianni A.;Ianni A.;James I.;Jollet C.;Keeter K.;Kendziora C. L.;Kobychev V.;Koh G.;Korablev D.;Korga G.;Kubankin A.;Li X.;Lissia M.;Lombardi P.;Luitz S.;Ma Y.;Machulin I. N.;Mandarano A.;Mari S. M.;Maricic J.;Marini L.;Martoff C. J.;Meregaglia A.;Meyers P. D.;Miletic T.;Milincic R.;Montanari D.;Monte A.;Montuschi M.;Monzani M.;Mosteiro P.;Mount B. J.;Muratova V. N.;Musico P.;Napolitano J.;Nelson A.;Odrowski S.;Orsini M.;Ortica F.;Pagani L.;Pallavicini M.;Pantic E.;Parmeggiano S.;Pelczar K.;Pelliccia N.;Perasso S.;Pocar A.;Pordes S.;Pugachev D. A.;Qian H.;Randle K.;Ranucci G.;Razeto A.;Reinhold B.;Renshaw A. L.;Romani A.;Rossi B.;Rossi N.;Rountree D.;Sablone D.;Saggese P.;Saldanha R.;Sands W.;Sangiorgio S.;Savarese C.;Segreto E.;Semenov D. A.;Shields E.;Singh P. N.;Skorokhvatov M. D.;Smirnov O.;Sotnikov A.;Stanford C.;Suvorov Y.;Tartaglia R.;Tatarowicz J.;Testera G.;Tonazzo A.;Trinchese P.;Unzhakov E. V.;Vishneva A.;Vogelaar B.;Wada M.;Walker S.;Wang H.;Wang Y.;Watson A. W.;Westerdale S.;Wilhelmi J.;Wojcik M. M.;Xiang X.;Xu J.;Yang C.;Yoo J.;Zavatarelli S.;Zec A.;Zhong W.;Zhu C.;Zuzel G.
2017
Abstract
The DarkSide-50 experiment, located at the “Laboratori Nazionali del Gran Sasso (INFN)”, is based on low-radioactivity argon double phase time projection chamber, surrounded by an active liquid scintillator veto, designed for the zero background achievement. The liquid argon features sufficient self shielding and easy scalability to multi-tons scale. The impressive reduction of the 39Ar isotope (compared to the atmospheric argon), along with the excellent pulse shape discrimination, make this technology a possible candidate for the forthcoming generation of multi-ton Dark Matter experiments.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/905696
Citazioni
ND
0
ND
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.