Background: In recent years, videolaryngoscopy has increasingly been utilized as an alternative to fiberoptic bronchoscopy in awake intubation. Nonetheless, it remains uncertain whether videolaryngoscopy represents a viable substitute for fiberoptic bronchoscopy. We conducted this systematic review with a meta-analysis to compare videolaryngoscopy and fiberoptic bronchoscopy for awake intubation. Methods: We systematically searched for all randomized controlled trials (RCTs) comparing videolaryngoscopy and fiberoptic bronchoscopy for awake intubation. The Cochrane Central Register of Controlled Trials (CENTRAL), Embase, and MEDLINE were systematically queried through August 2023. Our primary outcome measure was the duration of intubation. Secondary outcomes encompassed the rate of successful intubation on the initial attempt, failed intubation, patient-reported satisfaction, and any complications or adverse events potentially stemming from the intubation procedure. The Cochrane Risk of Bias Tool for RCTs was employed to evaluate all studies for evidence of bias. The GRADE approach was utilized to gauge the certainty of the evidence. Results: Eleven trials involving 873 patients were ultimately included in our review for data extraction. Meta-analysis demonstrated that videolaryngoscopy decreased the duration of intubation compared to fiberoptic bronchoscopy (SMD −1.9671 [95% CI: −2.7794 to −1.1548] p < 0.0001), a finding corroborated in subgroup analysis by the type of videolaryngoscope (SMD −2.5027 [95% CI: −4.8733 to −0.1322] p = 0.0385). Additionally, videolaryngoscopy marginally lowered the risk of experiencing a saturation below 90% during the procedure (RR −0.7040 [95% CI: −1.4038 to −0.0043] p = 0.0486). No statistically significant disparities were observed between the two techniques in terms of failed intubation, initial successful intubation attempt, or sore throat/hoarseness. With regard to patient-reported satisfaction, a pooled analysis was precluded due to the variability in evaluation methods employed across the trials to assess this outcome. Lastly, trial sequential analysis (TSA) conducted for intubation time (primary outcome) affirmed the conclusiveness of this evidence; TSA performed for secondary outcomes failed to yield conclusive evidence, indicating the necessity for further trials. Conclusions: Videolaryngoscopy for awake tracheal intubation diminishes intubation time and the risk of experiencing a saturation below 90% compared to fiberoptic bronchoscopy.

Videolaryngoscopy versus Fiberoptic Bronchoscopy for Awake Tracheal Intubation: A Systematic Review and Meta-Analysis of Randomized Controlled Trials / Merola, R.; Vargas, M.; Marra, A.; Buonanno, P.; Coviello, A.; Servillo, G.; Iacovazzo, C.. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - 13:11(2024). [10.3390/jcm13113186]

Videolaryngoscopy versus Fiberoptic Bronchoscopy for Awake Tracheal Intubation: A Systematic Review and Meta-Analysis of Randomized Controlled Trials

Merola R.;Vargas M.;Marra A.;Buonanno P.;Coviello A.;Servillo G.;Iacovazzo C.
2024

Abstract

Background: In recent years, videolaryngoscopy has increasingly been utilized as an alternative to fiberoptic bronchoscopy in awake intubation. Nonetheless, it remains uncertain whether videolaryngoscopy represents a viable substitute for fiberoptic bronchoscopy. We conducted this systematic review with a meta-analysis to compare videolaryngoscopy and fiberoptic bronchoscopy for awake intubation. Methods: We systematically searched for all randomized controlled trials (RCTs) comparing videolaryngoscopy and fiberoptic bronchoscopy for awake intubation. The Cochrane Central Register of Controlled Trials (CENTRAL), Embase, and MEDLINE were systematically queried through August 2023. Our primary outcome measure was the duration of intubation. Secondary outcomes encompassed the rate of successful intubation on the initial attempt, failed intubation, patient-reported satisfaction, and any complications or adverse events potentially stemming from the intubation procedure. The Cochrane Risk of Bias Tool for RCTs was employed to evaluate all studies for evidence of bias. The GRADE approach was utilized to gauge the certainty of the evidence. Results: Eleven trials involving 873 patients were ultimately included in our review for data extraction. Meta-analysis demonstrated that videolaryngoscopy decreased the duration of intubation compared to fiberoptic bronchoscopy (SMD −1.9671 [95% CI: −2.7794 to −1.1548] p < 0.0001), a finding corroborated in subgroup analysis by the type of videolaryngoscope (SMD −2.5027 [95% CI: −4.8733 to −0.1322] p = 0.0385). Additionally, videolaryngoscopy marginally lowered the risk of experiencing a saturation below 90% during the procedure (RR −0.7040 [95% CI: −1.4038 to −0.0043] p = 0.0486). No statistically significant disparities were observed between the two techniques in terms of failed intubation, initial successful intubation attempt, or sore throat/hoarseness. With regard to patient-reported satisfaction, a pooled analysis was precluded due to the variability in evaluation methods employed across the trials to assess this outcome. Lastly, trial sequential analysis (TSA) conducted for intubation time (primary outcome) affirmed the conclusiveness of this evidence; TSA performed for secondary outcomes failed to yield conclusive evidence, indicating the necessity for further trials. Conclusions: Videolaryngoscopy for awake tracheal intubation diminishes intubation time and the risk of experiencing a saturation below 90% compared to fiberoptic bronchoscopy.
2024
Videolaryngoscopy versus Fiberoptic Bronchoscopy for Awake Tracheal Intubation: A Systematic Review and Meta-Analysis of Randomized Controlled Trials / Merola, R.; Vargas, M.; Marra, A.; Buonanno, P.; Coviello, A.; Servillo, G.; Iacovazzo, C.. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - 13:11(2024). [10.3390/jcm13113186]
File in questo prodotto:
File Dimensione Formato  
jcm-13-03186.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Dominio pubblico
Dimensione 2.48 MB
Formato Adobe PDF
2.48 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/964566
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact