Endovascular repair of aneurysmal pathology in the aorto-iliac district presents one of the significant challenges in contemporary vascular surgery. Advances in techniques, materials, and devices have enhanced the ability of vascular surgeons in endovascular procedures, leading to the management of increasingly complex cases, with applications sometimes extending beyond the Instructions for Use (IFUs) of specific devices. In our case report, we describe the successful endovascular retrieval of a disconnected tip from an iliac branch device (IBD), preventing conversion to open surgery in a 73-year-old patient with a complex aortoiliac aneurysm. The case highlights the importance of exercising caution when treating patients with complex anatomy not in conformance with a device's IFU, even in high-volume centers with extensive endovascular expertise.
Endovascular Retrieval of Disconnected Tip From an Iliac Branch Device Stent Graft: A Case Report / Calicchio, Ilaria; Rinaldi, Antonia; Cantile, Nicola; Vollono, Michele; Del Guercio, Luca; Bracale, Umberto Marcello; Turchino, Davide. - In: ANNALI ITALIANI DI CHIRURGIA. - ISSN 2239-253X. - 96:5(2025), pp. 572-578. [10.62713/aic.3784]
Endovascular Retrieval of Disconnected Tip From an Iliac Branch Device Stent Graft: A Case Report
Calicchio, Ilaria;Rinaldi, Antonia;Cantile, Nicola;Vollono, Michele;Del Guercio, Luca;Bracale, Umberto Marcello;Turchino, Davide
2025
Abstract
Endovascular repair of aneurysmal pathology in the aorto-iliac district presents one of the significant challenges in contemporary vascular surgery. Advances in techniques, materials, and devices have enhanced the ability of vascular surgeons in endovascular procedures, leading to the management of increasingly complex cases, with applications sometimes extending beyond the Instructions for Use (IFUs) of specific devices. In our case report, we describe the successful endovascular retrieval of a disconnected tip from an iliac branch device (IBD), preventing conversion to open surgery in a 73-year-old patient with a complex aortoiliac aneurysm. The case highlights the importance of exercising caution when treating patients with complex anatomy not in conformance with a device's IFU, even in high-volume centers with extensive endovascular expertise.| File | Dimensione | Formato | |
|---|---|---|---|
|
calicchio ann ital chir 2025 PDF.js viewer.pdf
accesso aperto
Licenza:
Copyright dell'editore
Dimensione
6.1 MB
Formato
Adobe PDF
|
6.1 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.