Crystal Eye is a space-based all-sky monitor optimized for the autonomous detection and localization of transients in the 10 keV to 30 MeV energy range, a region where extensive observations and monitoring of various astrophysical phenomena are required. By focusing on the operating environment and its impact on the observation process, we optimized the detector design and assessed its scientific potential. We explored the use of novel techniques to achieve the science goals of the experiment. We assumed the orbit of a potential future mission at approximately 550 km altitude near the equatorial region with a 20° inclination. In such an orbit, the main background contributions for this kind of detector are from different particles and radiation of cosmic origin and secondaries produced by their interaction in the Earth's atmospheric and geomagnetic environment. We studied the response of Crystal Eye detector in this background environment, using the Geant4 Monte Carlo simulation toolkit. We also calculated other detector performance parameters to estimate its scientific capabilities. The effective area and efficiency of the detector are calculated for low energy γ-ray sources and used to estimate its sensitivity to short-duration transient sources. The calculation shows a better effective area and sensitivity by several factors compared to existing instruments of similar type. A method is also developed and discussed to estimate the online transient-localization performance of the detector, suggesting a better localization precision by about an order of magnitude than those typically reported by existing γ-ray monitors. We present here the simulation study and results of an innovative detector design concept that can make a significant contribution in the multi-messenger era. Moreover, this study can be useful as a technical reference for similar future experiments.
Crystal Eye: All sky MeV monitor with high precision real-time localization / Aloisio, R.; Atalay, U.; Banerjee, B.; Barbato, F. C. T.; Bissaldi, E.; Branchesi, M.; Capitanio, F.; Casilli, E.; Colalillo, R.; De Mitri, I.; De Santis, A.; Di Giovanni, A.; Alonso, M. F.; Fontanella, G.; Gargano, F.; Garufi, F.; Guarino, F.; Kyratzis, D.; Lima, H.; Loparco, F.; Longo, F.; Martinelli, R.; Montaruli, T.; Oganesyan, G.; Rico, J.; Santoliquido, F.; Sarkar, R.; Savina, P.; Siddique, I.; Smirnov, A.; Tambone, M.; Tarana, A.; Tykhonov, A.; Valore, L.; Vigliano, A. A.; Wu, L.. - In: ASTROPARTICLE PHYSICS. - ISSN 0927-6505. - 174:(2026). [10.1016/j.astropartphys.2025.103171]
Crystal Eye: All sky MeV monitor with high precision real-time localization
Colalillo R.;Garufi F.;Guarino F.;Tambone M.;Valore L.;
2026
Abstract
Crystal Eye is a space-based all-sky monitor optimized for the autonomous detection and localization of transients in the 10 keV to 30 MeV energy range, a region where extensive observations and monitoring of various astrophysical phenomena are required. By focusing on the operating environment and its impact on the observation process, we optimized the detector design and assessed its scientific potential. We explored the use of novel techniques to achieve the science goals of the experiment. We assumed the orbit of a potential future mission at approximately 550 km altitude near the equatorial region with a 20° inclination. In such an orbit, the main background contributions for this kind of detector are from different particles and radiation of cosmic origin and secondaries produced by their interaction in the Earth's atmospheric and geomagnetic environment. We studied the response of Crystal Eye detector in this background environment, using the Geant4 Monte Carlo simulation toolkit. We also calculated other detector performance parameters to estimate its scientific capabilities. The effective area and efficiency of the detector are calculated for low energy γ-ray sources and used to estimate its sensitivity to short-duration transient sources. The calculation shows a better effective area and sensitivity by several factors compared to existing instruments of similar type. A method is also developed and discussed to estimate the online transient-localization performance of the detector, suggesting a better localization precision by about an order of magnitude than those typically reported by existing γ-ray monitors. We present here the simulation study and results of an innovative detector design concept that can make a significant contribution in the multi-messenger era. Moreover, this study can be useful as a technical reference for similar future experiments.| File | Dimensione | Formato | |
|---|---|---|---|
|
1-s2.0-S0927650525000945-main-1.pdf
accesso aperto
Licenza:
Dominio pubblico
Dimensione
2.6 MB
Formato
Adobe PDF
|
2.6 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


