We present the design and preliminary imaging evaluation of a bench-top apparatus for X-ray cone-beam breast computed tomography (CBBCT), assembled for technical evaluation and for laboratory tests of various optimization techniques for CBBCT. The prototype is characterized by the computer control of the X-ray tube (W anode, 35-80 kVp, 0.25 mA, 50 /μm focal spot size), CsI:Tl CMOS flat panel detector (12 × 12 cm2 area, 50 /μm pitch, up to 9 fps at 4 × 4 binning), motorized translation and rotation stages with eight degrees of freedom, and fan-beam or cone-beam backprojection software. First cone-beam tomo- graphic images of two 14-cm diameter hemiellipsoidal PMMA breast phantoms are presented. © 2010 IEEE.

X-ray cone-beam breast computed tomography: Phantom studies / Russo, P., Mettivier, G., Lauria, A., Montesi, M.C.. - In: IEEE TRANSACTIONS ON NUCLEAR SCIENCE. - ISSN 0018-9499. - 57:1 PART 1(2010), pp. 160-172. [10.1109/TNS.2009.2034373]

X-ray cone-beam breast computed tomography: Phantom studies

Russo, P.
Primo
;
Mettivier, G.;Lauria, A.;Montesi, M. C.
2010

Abstract

We present the design and preliminary imaging evaluation of a bench-top apparatus for X-ray cone-beam breast computed tomography (CBBCT), assembled for technical evaluation and for laboratory tests of various optimization techniques for CBBCT. The prototype is characterized by the computer control of the X-ray tube (W anode, 35-80 kVp, 0.25 mA, 50 /μm focal spot size), CsI:Tl CMOS flat panel detector (12 × 12 cm2 area, 50 /μm pitch, up to 9 fps at 4 × 4 binning), motorized translation and rotation stages with eight degrees of freedom, and fan-beam or cone-beam backprojection software. First cone-beam tomo- graphic images of two 14-cm diameter hemiellipsoidal PMMA breast phantoms are presented. © 2010 IEEE.
2010
X-ray cone-beam breast computed tomography: Phantom studies / Russo, P., Mettivier, G., Lauria, A., Montesi, M.C.. - In: IEEE TRANSACTIONS ON NUCLEAR SCIENCE. - ISSN 0018-9499. - 57:1 PART 1(2010), pp. 160-172. [10.1109/TNS.2009.2034373]
File in questo prodotto:
File Dimensione Formato  
X-ray_Cone-Beam_Breast_Computed_Tomography_Phantom_Studies-1.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 1.88 MB
Formato Adobe PDF
1.88 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/1053117
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 26
  • ???jsp.display-item.citation.isi??? 23
social impact