Introduction: Chromium (Cr), and particularly its hexavalent form is classified as a Group 1 human carcinogen and represents a major occupational hazard, particularly in stainless-steel welding. This exploratory study integrated environmental and biological monitoring to characterize welders’ exposure and assessed how analytical methods influence exposure estimates. Methods: Twenty-two welders from two Northern Italian companies and 10 administrative controls were enrolled (May–June 2025) and monitored during full 8 h shifts. Personal respirable particulate samples were analyzed for total Cr (CrTOT) and Cr(VI) using NIOSH 7,600 and a speciation-preserving modified ISO 17075 protocol. Biological monitoring included pre-/post-shift urinary Cr (U-Cr, creatinine-adjusted) and post-shift exhaled breath condensate Cr (EBC-Cr). Results: All airborne CrTOT and Cr(VI) concentrations were below their respective Occupational Exposure Limit Values (500 and 5 μg/m 3 , respectively), though welders consistently showed higher exposure than controls. MMA welding produced the highest CrTOT and Cr(VI) levels. NIOSH 7600 yielded higher Cr(VI) values than the modified ISO method, a pattern consistent with a possible positive bias related to species interconversion during extraction. U-Cr was significantly elevated in welders at both sampling times [geometric mean (GM): 0.34, 0.36, and 0.05μg/g creatinine in pre-, post-shift exposed workers and controls, respectively], whereas EBC-Cr did not di􀀀er between groups (GM: 0.08 μg/L in all samples). Biomarker levels showed minimal variation across demographic and occupational subgroups. Correlations between airborne Cr and biological indicators were weak, yet U-Cr values in welders exceeded population reference ranges, indicating a clear occupational contribution despite low absolute exposure. Discussion: Integrated monitoring confirmed Cr absorption in welders despite regulatory compliance. Within the limits of this study, U-Cr appeared to be the most informative biomarker, whereas EBC-Cr showed limited sensitivity. Although exposures remained below biological limit values, welders exhibited an upward shift in U-Cr relative to background populations, supporting continued exposure minimization-especially for high-emission processes such as MMA- consistent with As Low As Reasonably Achievable principles.

Occupational exposure to total and hexavalent chromium in welders: an integrated environmental and biological monitoring study / Spinazzè, A., Leso, V., Della Notte, S., Zellino, C., Cattaneo, A., Recchia, S., Dossi, C., Grignani, E., Cavallo, D.m., Iavicoli, I.. - In: FRONTIERS IN PUBLIC HEALTH. - ISSN 2296-2565. - 14:(2026).

Occupational exposure to total and hexavalent chromium in welders: an integrated environmental and biological monitoring study

Leso V;Della Notte S;Iavicoli I.
2026

Abstract

Introduction: Chromium (Cr), and particularly its hexavalent form is classified as a Group 1 human carcinogen and represents a major occupational hazard, particularly in stainless-steel welding. This exploratory study integrated environmental and biological monitoring to characterize welders’ exposure and assessed how analytical methods influence exposure estimates. Methods: Twenty-two welders from two Northern Italian companies and 10 administrative controls were enrolled (May–June 2025) and monitored during full 8 h shifts. Personal respirable particulate samples were analyzed for total Cr (CrTOT) and Cr(VI) using NIOSH 7,600 and a speciation-preserving modified ISO 17075 protocol. Biological monitoring included pre-/post-shift urinary Cr (U-Cr, creatinine-adjusted) and post-shift exhaled breath condensate Cr (EBC-Cr). Results: All airborne CrTOT and Cr(VI) concentrations were below their respective Occupational Exposure Limit Values (500 and 5 μg/m 3 , respectively), though welders consistently showed higher exposure than controls. MMA welding produced the highest CrTOT and Cr(VI) levels. NIOSH 7600 yielded higher Cr(VI) values than the modified ISO method, a pattern consistent with a possible positive bias related to species interconversion during extraction. U-Cr was significantly elevated in welders at both sampling times [geometric mean (GM): 0.34, 0.36, and 0.05μg/g creatinine in pre-, post-shift exposed workers and controls, respectively], whereas EBC-Cr did not di􀀀er between groups (GM: 0.08 μg/L in all samples). Biomarker levels showed minimal variation across demographic and occupational subgroups. Correlations between airborne Cr and biological indicators were weak, yet U-Cr values in welders exceeded population reference ranges, indicating a clear occupational contribution despite low absolute exposure. Discussion: Integrated monitoring confirmed Cr absorption in welders despite regulatory compliance. Within the limits of this study, U-Cr appeared to be the most informative biomarker, whereas EBC-Cr showed limited sensitivity. Although exposures remained below biological limit values, welders exhibited an upward shift in U-Cr relative to background populations, supporting continued exposure minimization-especially for high-emission processes such as MMA- consistent with As Low As Reasonably Achievable principles.
2026
Occupational exposure to total and hexavalent chromium in welders: an integrated environmental and biological monitoring study / Spinazzè, A., Leso, V., Della Notte, S., Zellino, C., Cattaneo, A., Recchia, S., Dossi, C., Grignani, E., Cavallo, D.m., Iavicoli, I.. - In: FRONTIERS IN PUBLIC HEALTH. - ISSN 2296-2565. - 14:(2026).
File in questo prodotto:
File Dimensione Formato  
fpubh-14-1830673 (1).pdf

accesso aperto

Licenza: Copyright dell'editore
Dimensione 564.46 kB
Formato Adobe PDF
564.46 kB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/1072196
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact