In the framework of an experimental program to study the possibility of using a silicon crystal for X-ray detection in the diagnostic energy range (10-100 keV), the authors present the first experimental results obtained with a silicon detector (300 mu m thick, 1.4*1.4 cm2 surface) with microstrips deposited on each side: 25 mu m spacing on the junction side and 50 mu m spacing on the ohmic side: 25 mu m spacing on the junction side and 50 mu m spacing on the ohmic side; the read-out pitch is 100 mu m for both sides. Energy and spatial resolutions have been measured by means of collimated radioactive sources: 241Am (E gamma =60 keV) and 109Cd (E gamma =24 and 88 keV). A very good linearity in the response to the photon energy has been measured. Tantalum wires, i.e. high contrast objects, have been used as phantoms when exposing the detector to the 60 keV photons; the authors present the images thus obtained.

First X-ray images with a double-sided microstrips silicon crystal. A novel detector for digital radiography? / Alfano, B; Bandettini, A; Bencivelli, W; Bertolucci, Ennio; Bottigli, U; Conti, Maurizio; Del Guerra, A; Fantacci, Me; Penkowski, M; Randaccio, P; Rosso, V; Russo, Paolo. - In: PHYSICS IN MEDICINE AND BIOLOGY. - ISSN 0031-9155. - STAMPA. - 37:5(1992), pp. 1167-1170. [10.1088/0031-9155/37/5/010]

First X-ray images with a double-sided microstrips silicon crystal. A novel detector for digital radiography?

BERTOLUCCI, ENNIO;CONTI, MAURIZIO;RUSSO, PAOLO
1992

Abstract

In the framework of an experimental program to study the possibility of using a silicon crystal for X-ray detection in the diagnostic energy range (10-100 keV), the authors present the first experimental results obtained with a silicon detector (300 mu m thick, 1.4*1.4 cm2 surface) with microstrips deposited on each side: 25 mu m spacing on the junction side and 50 mu m spacing on the ohmic side: 25 mu m spacing on the junction side and 50 mu m spacing on the ohmic side; the read-out pitch is 100 mu m for both sides. Energy and spatial resolutions have been measured by means of collimated radioactive sources: 241Am (E gamma =60 keV) and 109Cd (E gamma =24 and 88 keV). A very good linearity in the response to the photon energy has been measured. Tantalum wires, i.e. high contrast objects, have been used as phantoms when exposing the detector to the 60 keV photons; the authors present the images thus obtained.
1992
First X-ray images with a double-sided microstrips silicon crystal. A novel detector for digital radiography? / Alfano, B; Bandettini, A; Bencivelli, W; Bertolucci, Ennio; Bottigli, U; Conti, Maurizio; Del Guerra, A; Fantacci, Me; Penkowski, M; Randaccio, P; Rosso, V; Russo, Paolo. - In: PHYSICS IN MEDICINE AND BIOLOGY. - ISSN 0031-9155. - STAMPA. - 37:5(1992), pp. 1167-1170. [10.1088/0031-9155/37/5/010]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/161543
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 11
social impact