Rapamycin is a potent immunosuppressive drug capable of significantly reducing acute graft rejection in kidney, liver and heart transplant patients. Its immunosuppressive activity and adverse effects have been related to rapamycin concentration, and therapeutic drug monitoring of the drug is deemed appropriate. This work was aimed at developing a new quantification method based on the isolation of the [M+Na]+ ion as precursor and its further fragmentation through an ion trap mass spectrometer equipped with an electrospray ionization source. A limit of detection (LOD) of 0.7 ng/mL was obtained, while the lower limit of quantification (LLOQ) was 2.4 ng/mL. The accuracy and reproducibility of the responses were evaluated and compared with results obtained when the [M+Na]+ ion was chosen as the precursor in a triple quadrupole mass spectrometer. In this case the LOD was 0.5 ng/mL and the LLOQ 1.7 ng/mL. Data showed that it would be possible to use the quantification of the sodiated species for the routine determination of rapamycin, as an alternative to the commonly adopted method based on the ammoniated complex.
Determination of rapamycin: quantification of the sodiated species by an ion trap mass spectrometer as an alternative to the ammoniated complex analysis by triple quadrupole / Pieri, Maria; Miraglia, N.; Castiglia, L.; Genovese, G.; Basilicata, P.; Simonelli, A.; Acampora, Antonio. - In: RAPID COMMUNICATIONS IN MASS SPECTROMETRY. - ISSN 0951-4198. - STAMPA. - 19:21(2005), pp. 3042-3050.
Determination of rapamycin: quantification of the sodiated species by an ion trap mass spectrometer as an alternative to the ammoniated complex analysis by triple quadrupole
PIERI, MARIA;P. Basilicata;ACAMPORA, ANTONIO
2005
Abstract
Rapamycin is a potent immunosuppressive drug capable of significantly reducing acute graft rejection in kidney, liver and heart transplant patients. Its immunosuppressive activity and adverse effects have been related to rapamycin concentration, and therapeutic drug monitoring of the drug is deemed appropriate. This work was aimed at developing a new quantification method based on the isolation of the [M+Na]+ ion as precursor and its further fragmentation through an ion trap mass spectrometer equipped with an electrospray ionization source. A limit of detection (LOD) of 0.7 ng/mL was obtained, while the lower limit of quantification (LLOQ) was 2.4 ng/mL. The accuracy and reproducibility of the responses were evaluated and compared with results obtained when the [M+Na]+ ion was chosen as the precursor in a triple quadrupole mass spectrometer. In this case the LOD was 0.5 ng/mL and the LLOQ 1.7 ng/mL. Data showed that it would be possible to use the quantification of the sodiated species for the routine determination of rapamycin, as an alternative to the commonly adopted method based on the ammoniated complex.File | Dimensione | Formato | |
---|---|---|---|
RCM 2005 Rapamicina.pdf
non disponibili
Tipologia:
Documento in Post-print
Licenza:
Accesso privato/ristretto
Dimensione
264.34 kB
Formato
Adobe PDF
|
264.34 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.