The results of 131I metaiodobenzylguanidine (MIBG) and Computed Tomography (CT) scans in a group of patients with clinically suspected pheochromocytoma were evaluated and compared with biohumoral parameters. We studied 24 consecutive patients (7 M and 17 F; age range 20-66 years). 131I-MIBG scintigraphy and CT were in agreement in 19 patients (79%): of them 7 cases were true positive, and 12 were true negative. Disagreement between the two imaging techniques was observed in 5 patients (21%). In this group, one patient, with positive CT scan, had false negative MIBG study, while 4 patients with negative MIBG scan, had false positive CT. MIBG showed significantly higher (p less than 0.05) specificity (100%), positive predictive value (100%), and accuracy (96%) than CT (75%, 67%, and 83%, respectively). 131I-MIBG scintigraphy is an accurate, noninvasive technique for localizing pheochromocytoma and providing direct tissue characterization, while CT provides more accurate spatial information. In conclusion, CT and MIBG studies are complementary in the evaluation of patients with suspected pheochromocytoma

La scintigrafia con 131I metaiodobenzilguanidina in pazienti con sospetto feocromocitoma: confronto con TC e parametri bioumorali / Maurelli, L; Cuocolo, A; Lastoria, S; Brunetti, Arturo; Maurea, Simone; Lembo, G; Klain, M; Caracò, C; Salvatore, M.. - In: LA RADIOLOGIA MEDICA. - ISSN 0033-8362. - STAMPA. - 82:(1991), pp. 839-843.

La scintigrafia con 131I metaiodobenzilguanidina in pazienti con sospetto feocromocitoma: confronto con TC e parametri bioumorali

BRUNETTI, ARTURO;MAUREA, SIMONE;Klain M;
1991

Abstract

The results of 131I metaiodobenzylguanidine (MIBG) and Computed Tomography (CT) scans in a group of patients with clinically suspected pheochromocytoma were evaluated and compared with biohumoral parameters. We studied 24 consecutive patients (7 M and 17 F; age range 20-66 years). 131I-MIBG scintigraphy and CT were in agreement in 19 patients (79%): of them 7 cases were true positive, and 12 were true negative. Disagreement between the two imaging techniques was observed in 5 patients (21%). In this group, one patient, with positive CT scan, had false negative MIBG study, while 4 patients with negative MIBG scan, had false positive CT. MIBG showed significantly higher (p less than 0.05) specificity (100%), positive predictive value (100%), and accuracy (96%) than CT (75%, 67%, and 83%, respectively). 131I-MIBG scintigraphy is an accurate, noninvasive technique for localizing pheochromocytoma and providing direct tissue characterization, while CT provides more accurate spatial information. In conclusion, CT and MIBG studies are complementary in the evaluation of patients with suspected pheochromocytoma
1991
La scintigrafia con 131I metaiodobenzilguanidina in pazienti con sospetto feocromocitoma: confronto con TC e parametri bioumorali / Maurelli, L; Cuocolo, A; Lastoria, S; Brunetti, Arturo; Maurea, Simone; Lembo, G; Klain, M; Caracò, C; Salvatore, M.. - In: LA RADIOLOGIA MEDICA. - ISSN 0033-8362. - STAMPA. - 82:(1991), pp. 839-843.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/344446
Citazioni
  • ???jsp.display-item.citation.pmc??? 0
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact