We present the evaluation of the induced voltages in a lossless single transmission line, located at a given height over an infinite conductivity ground plane, and exited by an external field due to a step current moving along a vertical channel. This is a classic topic of the theory of lightning-induced voltages on power lines. The technical literature related to this topic has performed a significant effort; however, only approximated formulas have been obtained so far. In this paper, we derive the exact closed-form solution. We also will discuss, evaluate, and compare the approximated formulas with reference to the proposed exact one, thus contributing to clarifying a matter that still is debated and sometimes misleading, as we will show in the paper. We furthermore recall that the examined lightning-induced voltages model is fundamental for the IEEE standard 1410, a guide for improving the lightning performance of power distribution line.

An Exact Closed-Form Solution for Lightning-Induced Overvoltages Calculations / Andreotti, Amedeo; Assante, D.; Mottola, Fabio; Verolino, Luigi. - In: IEEE TRANSACTIONS ON POWER DELIVERY. - ISSN 0885-8977. - STAMPA. - 24(3):(2009), pp. 1328-1343. [10.1109/TPWRD.2008.2005395]

An Exact Closed-Form Solution for Lightning-Induced Overvoltages Calculations

ANDREOTTI, AMEDEO;MOTTOLA, FABIO;VEROLINO, LUIGI
2009

Abstract

We present the evaluation of the induced voltages in a lossless single transmission line, located at a given height over an infinite conductivity ground plane, and exited by an external field due to a step current moving along a vertical channel. This is a classic topic of the theory of lightning-induced voltages on power lines. The technical literature related to this topic has performed a significant effort; however, only approximated formulas have been obtained so far. In this paper, we derive the exact closed-form solution. We also will discuss, evaluate, and compare the approximated formulas with reference to the proposed exact one, thus contributing to clarifying a matter that still is debated and sometimes misleading, as we will show in the paper. We furthermore recall that the examined lightning-induced voltages model is fundamental for the IEEE standard 1410, a guide for improving the lightning performance of power distribution line.
2009
An Exact Closed-Form Solution for Lightning-Induced Overvoltages Calculations / Andreotti, Amedeo; Assante, D.; Mottola, Fabio; Verolino, Luigi. - In: IEEE TRANSACTIONS ON POWER DELIVERY. - ISSN 0885-8977. - STAMPA. - 24(3):(2009), pp. 1328-1343. [10.1109/TPWRD.2008.2005395]
File in questo prodotto:
File Dimensione Formato  
TPD.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: Accesso privato/ristretto
Dimensione 474.54 kB
Formato Adobe PDF
474.54 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/349370
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 78
  • ???jsp.display-item.citation.isi??? 58
social impact