The paper describes the seismic retrofit (carried out in the period February-March 2006) of the “Our Lady of Tears Shrine” in Syracuse (Italy), made substituting the bearings supporting its impressive truncated-conical dome with sliding seismic isolators equipped with elasto-plastic dissipators. After an accurate description of the construction and of its new anti-seismic devices, installed between the dome and its 22 supporting columns, the dome raising and lowering phases, together with the instrumentation and data acquired during the operations, are reported in detail. The improving of the structural behaviour after seismic retrofit is demonstrated through the results of a numerical investigation of the Sanctuary under seismic excitation. Finally, the rehabilitation and reactivation of the pre-existent continuous monitoring system of the temple is examined in the last part of the paper. The structure has been recently included among those of the Italian network of buildings and bridges permanently monitored by the Italian Department of Civil Protection within the Seismic Observatory of Structures (OSS).

Application of structural isolation and health monitoring / Serino, Giorgio; Spizzuoco, Mariacristina; M. R., Marsico. - In: STRUCTURE AND INFRASTRUCTURE ENGINEERING. - ISSN 1573-2479. - STAMPA. - 6:5(2010), pp. 593-610.

Application of structural isolation and health monitoring

SERINO, GIORGIO;SPIZZUOCO, MARIACRISTINA;
2010

Abstract

The paper describes the seismic retrofit (carried out in the period February-March 2006) of the “Our Lady of Tears Shrine” in Syracuse (Italy), made substituting the bearings supporting its impressive truncated-conical dome with sliding seismic isolators equipped with elasto-plastic dissipators. After an accurate description of the construction and of its new anti-seismic devices, installed between the dome and its 22 supporting columns, the dome raising and lowering phases, together with the instrumentation and data acquired during the operations, are reported in detail. The improving of the structural behaviour after seismic retrofit is demonstrated through the results of a numerical investigation of the Sanctuary under seismic excitation. Finally, the rehabilitation and reactivation of the pre-existent continuous monitoring system of the temple is examined in the last part of the paper. The structure has been recently included among those of the Italian network of buildings and bridges permanently monitored by the Italian Department of Civil Protection within the Seismic Observatory of Structures (OSS).
2010
Application of structural isolation and health monitoring / Serino, Giorgio; Spizzuoco, Mariacristina; M. R., Marsico. - In: STRUCTURE AND INFRASTRUCTURE ENGINEERING. - ISSN 1573-2479. - STAMPA. - 6:5(2010), pp. 593-610.
File in questo prodotto:
File Dimensione Formato  
Serino - Application of structural isolation and health monitoring.pdf

non disponibili

Tipologia: Documento in Post-print
Licenza: Accesso privato/ristretto
Dimensione 4.36 MB
Formato Adobe PDF
4.36 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/351819
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 6
  • ???jsp.display-item.citation.isi??? ND
social impact