Vascular perfusion was assessed in 10 dogs without prostatic abnormalities and 26 dogs with prostatic disease using contrast-enhanced ultrasound. The time to reach peak contrast intensity (TTP) and peak perfusion intensity (PPI) were measured, and histological biopsies were collected from each dog. Biopsies confirmed normal prostate (n = 10), benign prostatic hyperplasia (n = 11), mixed benign pathology (n = 9), prostatitis (n = 1), prostatic malignancy [adenocar- cinoma (n = 4); leiomyosarcoma (n = 1)]. In normal dogs, mean PPI was 16.8% ± 5.8 SD, and mean TTP was 33.6 ± 6.4 s. Benign conditions overall were not statistically different from normal dogs (p > 0.05); for benign prostatic hyperplasia, mean PPI was 16.9 ± 3.8%, and mean TTP was 26.2 ± 5.8 s; for mixed benign pathology mean PPI was 14.8 ± 7.8%, and mean TTP was 31.9 ± 9.7 s; for prostatitis, PPI was 14.2%, and TTP was 25.9 s. The malignant conditions overall had perfusion values that differed from the normal dogs (p < 0.05), although evaluation of the data for individ- ual malignancies did not demonstrate a consistent trend; for adenocarcinomas, the PPI was numerically higher with a mean of 23.7 ± 1.9%, and the mean TTP was 26.9 ± 4.8 s, whilst for the dog with leiomyosarcoma values were numerically lower with a PPI of 14.1% and TTP of 41.3 s. Contrast- enhanced ultrasound appears to offer some ability to docu- ment differences in perfusion that may differentiate between malignant and benign lesions, although studies with larger numbers of animals are required to confirm this contention.

Assessment of vascular perfusion kinetics using contrast-enhanced ultrasound for the diagnosis of prostatic disease in dogs / Vignoli, M; Russo, Marco; Catone, G; Rossi, F; Attanasi, G; Terragni, R; Saunders, J; England, G.. - In: REPRODUCTION IN DOMESTIC ANIMALS. - ISSN 0936-6768. - 46:2(2011), pp. 209-213. [10.1111/j.1439-0531.2010.01629.x]

Assessment of vascular perfusion kinetics using contrast-enhanced ultrasound for the diagnosis of prostatic disease in dogs.

RUSSO, MARCO;
2011

Abstract

Vascular perfusion was assessed in 10 dogs without prostatic abnormalities and 26 dogs with prostatic disease using contrast-enhanced ultrasound. The time to reach peak contrast intensity (TTP) and peak perfusion intensity (PPI) were measured, and histological biopsies were collected from each dog. Biopsies confirmed normal prostate (n = 10), benign prostatic hyperplasia (n = 11), mixed benign pathology (n = 9), prostatitis (n = 1), prostatic malignancy [adenocar- cinoma (n = 4); leiomyosarcoma (n = 1)]. In normal dogs, mean PPI was 16.8% ± 5.8 SD, and mean TTP was 33.6 ± 6.4 s. Benign conditions overall were not statistically different from normal dogs (p > 0.05); for benign prostatic hyperplasia, mean PPI was 16.9 ± 3.8%, and mean TTP was 26.2 ± 5.8 s; for mixed benign pathology mean PPI was 14.8 ± 7.8%, and mean TTP was 31.9 ± 9.7 s; for prostatitis, PPI was 14.2%, and TTP was 25.9 s. The malignant conditions overall had perfusion values that differed from the normal dogs (p < 0.05), although evaluation of the data for individ- ual malignancies did not demonstrate a consistent trend; for adenocarcinomas, the PPI was numerically higher with a mean of 23.7 ± 1.9%, and the mean TTP was 26.9 ± 4.8 s, whilst for the dog with leiomyosarcoma values were numerically lower with a PPI of 14.1% and TTP of 41.3 s. Contrast- enhanced ultrasound appears to offer some ability to docu- ment differences in perfusion that may differentiate between malignant and benign lesions, although studies with larger numbers of animals are required to confirm this contention.
2011
Assessment of vascular perfusion kinetics using contrast-enhanced ultrasound for the diagnosis of prostatic disease in dogs / Vignoli, M; Russo, Marco; Catone, G; Rossi, F; Attanasi, G; Terragni, R; Saunders, J; England, G.. - In: REPRODUCTION IN DOMESTIC ANIMALS. - ISSN 0936-6768. - 46:2(2011), pp. 209-213. [10.1111/j.1439-0531.2010.01629.x]
File in questo prodotto:
File Dimensione Formato  
Assessment of Vascular Perfusion Kinetics Using Contrast-enhanced Ultrasound for.pdf

solo utenti autorizzati

Tipologia: Documento in Post-print
Licenza: Accesso privato/ristretto
Dimensione 360.84 kB
Formato Adobe PDF
360.84 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/412544
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 34
  • ???jsp.display-item.citation.isi??? 28
social impact