We have designed and tested 5 x 5 mm(2) chips containing island type STJs with different geometries, fabricated on Si substrates in the configuration Nb/Al-AlOx/Nb and using a NbN overlayer acting both as wiring and radiation absorber. The aim is to investigate the advantages of the trapping effect due to the Nb layer trap. In fact, for the NbN/Nb bilayer the scattering time is much faster than the values calculated for other Nb based bilayers, leading to more efficient trapping processes. The junctions have been characterized by tunneling and Josephson current measurements down to 0.5 K. Experimental results concerning the response of the devices under X-ray irradiation down to 60 mK are presented and discussed.

X-ray response of STJ detectors using NbN absorbing layers / Parlato, Loredana; Peluso, Giuseppe; Pepe, GIOVANNI PIERO; SCOTTI DI UCCIO, Umberto; R., Cristiano; E., Espositio; L., Frunzio; S., Pagano; H., Akoh; H., Nakagawa; S., Takada; M., Gutsche; H., Kraus. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 370:(1996), pp. 95-97. [10.1016/0168-9002(95)01060-2]

X-ray response of STJ detectors using NbN absorbing layers

PARLATO, LOREDANA;PELUSO, GIUSEPPE;PEPE, GIOVANNI PIERO;SCOTTI DI UCCIO, UMBERTO;
1996

Abstract

We have designed and tested 5 x 5 mm(2) chips containing island type STJs with different geometries, fabricated on Si substrates in the configuration Nb/Al-AlOx/Nb and using a NbN overlayer acting both as wiring and radiation absorber. The aim is to investigate the advantages of the trapping effect due to the Nb layer trap. In fact, for the NbN/Nb bilayer the scattering time is much faster than the values calculated for other Nb based bilayers, leading to more efficient trapping processes. The junctions have been characterized by tunneling and Josephson current measurements down to 0.5 K. Experimental results concerning the response of the devices under X-ray irradiation down to 60 mK are presented and discussed.
1996
X-ray response of STJ detectors using NbN absorbing layers / Parlato, Loredana; Peluso, Giuseppe; Pepe, GIOVANNI PIERO; SCOTTI DI UCCIO, Umberto; R., Cristiano; E., Espositio; L., Frunzio; S., Pagano; H., Akoh; H., Nakagawa; S., Takada; M., Gutsche; H., Kraus. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 370:(1996), pp. 95-97. [10.1016/0168-9002(95)01060-2]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/467420
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 1
  • ???jsp.display-item.citation.isi??? 1
social impact