A simple model is used to calculate the angular and time dependence of solar radiation. The resulting computer program is particularly suited to the evaluation of the performance of a solar system as a function of the collector area; it is used as a subroutine in a program determining the optimal dimensions of a solar system according to the criterion of minimum total (capital plus running) cost.
Long Term Performances Of Flat-Plate Solar Collectors / Ambrosone, Giuseppina; A., Andretta; Bloisi, Francesco; S., Catalanotti; V., Cuomo; V., Silvestrini; Vicari, LUCIANO ROSARIO MARIA. - In: APPLIED ENERGY. - ISSN 0306-2619. - STAMPA. - 7:(1980), pp. 119-128. [10.1016/0306-2619(80)90053-7]
Long Term Performances Of Flat-Plate Solar Collectors
AMBROSONE, GIUSEPPINA;BLOISI, FRANCESCO;VICARI, LUCIANO ROSARIO MARIA
1980
Abstract
A simple model is used to calculate the angular and time dependence of solar radiation. The resulting computer program is particularly suited to the evaluation of the performance of a solar system as a function of the collector area; it is used as a subroutine in a program determining the optimal dimensions of a solar system according to the criterion of minimum total (capital plus running) cost.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.