An apparatus for laser-induced time-resolved fluorescence measurements, in conjunction with pyrene derivatives endowed with long-lived excited singlet states, was employed for immunocytofluorometric measurements. N-(1-pyrene)maleimide, 1-pyrenesulfonyl chloride and 1-pyreneisothiocyanate were conjugated with immunoglobulin, antimouse-IgG, and the fluorescence decays of both free and conjugated forms were investigated. Bi-exponential decays were obtained in all cases with time constants of the short-lived component in the range 3-4.7 ns and the long-lived one in the range 20-55 ns. Only the spectral distribution of the two components is essentially affected upon conjugation. The persistence of the long-lived component, well above the lifetime of autofluorescence, and of the antibody specificity, as shown by immunodiffusion tests, upon conjugation indicates that this technique could be advantageously adopted in immunocytofluorometry.

Fluorochromes With Long-lived Fluorescence As Potential Labels For Pulsed-laser Immunocytofluorometry - Photophysical Characterization of Pyrene Derivatives / A., Andreoni; G., Bottiroli; A., Colasanti; M. C., Giangare; Riccio, Patrizia; Roberti, Giuseppe; P., Vaghi. - In: JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS. - ISSN 0165-022X. - STAMPA. - 29:(1994), pp. 157-172. [10.1016/0165-022X(94)90052-3]

Fluorochromes With Long-lived Fluorescence As Potential Labels For Pulsed-laser Immunocytofluorometry - Photophysical Characterization of Pyrene Derivatives

RICCIO, PATRIZIA;ROBERTI, GIUSEPPE;
1994

Abstract

An apparatus for laser-induced time-resolved fluorescence measurements, in conjunction with pyrene derivatives endowed with long-lived excited singlet states, was employed for immunocytofluorometric measurements. N-(1-pyrene)maleimide, 1-pyrenesulfonyl chloride and 1-pyreneisothiocyanate were conjugated with immunoglobulin, antimouse-IgG, and the fluorescence decays of both free and conjugated forms were investigated. Bi-exponential decays were obtained in all cases with time constants of the short-lived component in the range 3-4.7 ns and the long-lived one in the range 20-55 ns. Only the spectral distribution of the two components is essentially affected upon conjugation. The persistence of the long-lived component, well above the lifetime of autofluorescence, and of the antibody specificity, as shown by immunodiffusion tests, upon conjugation indicates that this technique could be advantageously adopted in immunocytofluorometry.
1994
Fluorochromes With Long-lived Fluorescence As Potential Labels For Pulsed-laser Immunocytofluorometry - Photophysical Characterization of Pyrene Derivatives / A., Andreoni; G., Bottiroli; A., Colasanti; M. C., Giangare; Riccio, Patrizia; Roberti, Giuseppe; P., Vaghi. - In: JOURNAL OF BIOCHEMICAL AND BIOPHYSICAL METHODS. - ISSN 0165-022X. - STAMPA. - 29:(1994), pp. 157-172. [10.1016/0165-022X(94)90052-3]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/497739
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 5
social impact