Despite significant improvements in stent platform, currently available bare-metal stents (BMS) are still associated with restenosis. Thin-strut design cobalt-chromium alloys hold the promise of improving results of BMS, especially when implanted with direct technique. We performed an observational study to appraise outcomes of the novel Skylor™ stent, stratifying outcomes according to stenting technique. We included all consecutive patients undergoing coronary stenting with Skylor™ at 2 centers between 2006 and 2009. The primary end-point was the long-term rate of major adverse cardiac events (MACE, i.e. death, myocardial infarction (MI), coronary artery bypass grafting (CABG) or target vessel revascularization (TVR)). As pre-specified analysis, we compared patients undergoing direct stenting versus those stent implantation following predilation. A total of 1020 patients were included (1292 Skylor™ stents), with procedural success obtained in 99%. Comparing patients undergoing direct stenting (66%) versus pre-dilation (34%) at 16�7 months of follow-up, MACE had occurred in, respectively, 8% versus 14% (p=0.001), with death in 1% versus 2= (p=0.380), MI in 1% versus 2% (p=0.032), CABG in 0.2% versus 2% (p=0.012), and TVR in 6% versus 9% [p=0.071]. Even at multivariable analysis with propensity adjustment, direct stenting was associated with significantly fewer MACE [hazard ratio 0.60 [0.38-0.93], p=0.024]. CONCLUSIONS: This observational study suggests the presence of a beneficial synergy between direct coronary stenting technique and use of the novel thin-strut cobalt-chromium Skylor™ stent in real-world patients undergoing PCI.
Synergy between direct coronary stenting technique and use of the novel thin strut cobalt chromium skylor™ stent: the mace in follow up patients treated with skylor stent [MILES Study] / Giordano, A.; Polimeno, M.; Corcione, N.; Fattore, L.; Di Lorenzo, L.; Biondi Zoccai, G.; Ferraro, P.; Romano, MARIA FIAMMETTA. - In: CURRENT CARDIOLOGY REVIEWS. - ISSN 1573-403X. - 8:1(2012), pp. 6-13. [10.2174/157340312801215818]
Synergy between direct coronary stenting technique and use of the novel thin strut cobalt chromium skylor™ stent: the mace in follow up patients treated with skylor stent [MILES Study].
ROMANO, MARIA FIAMMETTA
2012
Abstract
Despite significant improvements in stent platform, currently available bare-metal stents (BMS) are still associated with restenosis. Thin-strut design cobalt-chromium alloys hold the promise of improving results of BMS, especially when implanted with direct technique. We performed an observational study to appraise outcomes of the novel Skylor™ stent, stratifying outcomes according to stenting technique. We included all consecutive patients undergoing coronary stenting with Skylor™ at 2 centers between 2006 and 2009. The primary end-point was the long-term rate of major adverse cardiac events (MACE, i.e. death, myocardial infarction (MI), coronary artery bypass grafting (CABG) or target vessel revascularization (TVR)). As pre-specified analysis, we compared patients undergoing direct stenting versus those stent implantation following predilation. A total of 1020 patients were included (1292 Skylor™ stents), with procedural success obtained in 99%. Comparing patients undergoing direct stenting (66%) versus pre-dilation (34%) at 16�7 months of follow-up, MACE had occurred in, respectively, 8% versus 14% (p=0.001), with death in 1% versus 2= (p=0.380), MI in 1% versus 2% (p=0.032), CABG in 0.2% versus 2% (p=0.012), and TVR in 6% versus 9% [p=0.071]. Even at multivariable analysis with propensity adjustment, direct stenting was associated with significantly fewer MACE [hazard ratio 0.60 [0.38-0.93], p=0.024]. CONCLUSIONS: This observational study suggests the presence of a beneficial synergy between direct coronary stenting technique and use of the novel thin-strut cobalt-chromium Skylor™ stent in real-world patients undergoing PCI.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.