A case-control study on lung cancer and radon exposure in dwellings has been carried out in Lazio, a high indoor radon region of Central Italy. A total of about 400 cases and 400 controls were recruited and radon concentration was measured in a total of about 1850 dwellings. In each dwelling, radon concentration measurement devices were placed in both the main bedroom and livingroom for two consecutive six-month periods. Each radon device, enclosed in a sealed polyethylene bag, contains two LR 115 detectors, each beingcovered by a thin absorber to reduce the alpha-energy within the detector sensitive range. A quality assurance program, described in this paper, was applied in order to reduce radon concentration measurement uncertainty, which have a signi7cant impact on the results of an epidemiological study. The reported internal quality control and intercomparison results are compared with the results of other studies, and show that the radon measurement precision and accuracy obtained in this study can be considered quite good.

Quality assurance program for LR 115 based radonconcentration measurements in a case-control study:description and results / F., Bochicchio; F., Forastiere; S., Farchi; D., Marocco; Quarto, Maria; F., Sera. - In: RADIATION MEASUREMENTS. - ISSN 1350-4487. - ELETTRONICO. - 36:(2003), pp. 205-210. [10.1016/S1350-4487(03)00124-0]

Quality assurance program for LR 115 based radonconcentration measurements in a case-control study:description and results

QUARTO, MARIA;
2003

Abstract

A case-control study on lung cancer and radon exposure in dwellings has been carried out in Lazio, a high indoor radon region of Central Italy. A total of about 400 cases and 400 controls were recruited and radon concentration was measured in a total of about 1850 dwellings. In each dwelling, radon concentration measurement devices were placed in both the main bedroom and livingroom for two consecutive six-month periods. Each radon device, enclosed in a sealed polyethylene bag, contains two LR 115 detectors, each beingcovered by a thin absorber to reduce the alpha-energy within the detector sensitive range. A quality assurance program, described in this paper, was applied in order to reduce radon concentration measurement uncertainty, which have a signi7cant impact on the results of an epidemiological study. The reported internal quality control and intercomparison results are compared with the results of other studies, and show that the radon measurement precision and accuracy obtained in this study can be considered quite good.
2003
Quality assurance program for LR 115 based radonconcentration measurements in a case-control study:description and results / F., Bochicchio; F., Forastiere; S., Farchi; D., Marocco; Quarto, Maria; F., Sera. - In: RADIATION MEASUREMENTS. - ISSN 1350-4487. - ELETTRONICO. - 36:(2003), pp. 205-210. [10.1016/S1350-4487(03)00124-0]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/514206
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 16
social impact