A general purpose detector, KLOE, is under construction for operations at the Frascati phi factory, DA Phi NE. Its central mission is the study of direct CP violation in K-0 decays, which places very stringent requirements on electromagnetic shower measurements in the 20-280 MeV/c region. We have chosen to use a lead-scintillator sampling calorimeter, EmC, consisting of very thin (0.5 mm) lead layers in which are embedded 1 mm diameter scintillating fibers. Much prototyping and testing has been done during its design, yielding, for the final EmC, an expected energy resolution of sigma(E)/E similar to 4.4%/root E(GeV) and a time resolution of similar to 46 ps/root E(GeV), with excellent linearity in the region of interest and with little dependence on incidence angle and entry position.

The KLOE electromagnetic calorimeter / Juliet Lee, Franzini; A., Antonelli; M., Antonelli; G., Barbiellini; M., Barone; S., Bertolucci; C., Bini; C., Bloise; V., Bolognesi; F., Bossi; P., Campana; F., Cervelli; R., Caloi; M., Cordelli; G., De Zorzi; G., Di Cosimo; A., Di Domenico; O., Erriquez; A., Farilla; A., Ferrari; P., Franzini; Garufi, Fabio; P., Gauzzi; E., Gero; S., Giovannella; R., Haydar; M., Incagli; L., Keeble; W., Kim; G., Lanfranchi; A., Martini; A., Martinis; S., Miscetti; F., Murtas; A., Parri; A., Passeri; F., Scuri; E., Spiriti; L., Tortora; X. L., Wang; S., Wölfle. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 360:(1995), pp. 201-205. [10.1016/0168-9002(94)01607-0]

The KLOE electromagnetic calorimeter

GARUFI, FABIO;
1995

Abstract

A general purpose detector, KLOE, is under construction for operations at the Frascati phi factory, DA Phi NE. Its central mission is the study of direct CP violation in K-0 decays, which places very stringent requirements on electromagnetic shower measurements in the 20-280 MeV/c region. We have chosen to use a lead-scintillator sampling calorimeter, EmC, consisting of very thin (0.5 mm) lead layers in which are embedded 1 mm diameter scintillating fibers. Much prototyping and testing has been done during its design, yielding, for the final EmC, an expected energy resolution of sigma(E)/E similar to 4.4%/root E(GeV) and a time resolution of similar to 46 ps/root E(GeV), with excellent linearity in the region of interest and with little dependence on incidence angle and entry position.
1995
The KLOE electromagnetic calorimeter / Juliet Lee, Franzini; A., Antonelli; M., Antonelli; G., Barbiellini; M., Barone; S., Bertolucci; C., Bini; C., Bloise; V., Bolognesi; F., Bossi; P., Campana; F., Cervelli; R., Caloi; M., Cordelli; G., De Zorzi; G., Di Cosimo; A., Di Domenico; O., Erriquez; A., Farilla; A., Ferrari; P., Franzini; Garufi, Fabio; P., Gauzzi; E., Gero; S., Giovannella; R., Haydar; M., Incagli; L., Keeble; W., Kim; G., Lanfranchi; A., Martini; A., Martinis; S., Miscetti; F., Murtas; A., Parri; A., Passeri; F., Scuri; E., Spiriti; L., Tortora; X. L., Wang; S., Wölfle. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 360:(1995), pp. 201-205. [10.1016/0168-9002(94)01607-0]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/516591
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
social impact