Cleaning and shaping are important section for the root canal treatment. A number of different methodologies have been developed to overcome these problems, including the introduction of rotary instruments nickel-titanium (NiTi). In endodontics NiTi have been shown to significantly reduce procedural errors compared to manual techniques of instrumentation. The efficiency of files is related to many factor. Although previous investigations that have used μCT analysis were hampered by insufficient resolution or projection incorrect. The new generation of μCT performance best offer, as micron resolution and accurate measurement software for evaluating the accurate anatomy of the root canal. The aim the paper was to evaluate the efficiency of Reciproc files in root canal treatment, evaluated before and after instrumentation by using μ-CT analysis

μcT analysis of mandibular molars before and after instrumentation by Reciproc files [Analisi anatomiche di molari mandibolari pre- e post-strumentazione con Reciproc mediante μtC] / Ametrano, Gianluca; Riccitiello, Francesco; Amato, M.; Formisano, A.; Muto, M; Grassi, R.; Valletta, A.; Simeone, Michele. - In: RECENTI PROGRESSI IN MEDICINA. - ISSN 0034-1193. - 104:7(2013), pp. 420-424. [10.1701/1315.14589]

μcT analysis of mandibular molars before and after instrumentation by Reciproc files [Analisi anatomiche di molari mandibolari pre- e post-strumentazione con Reciproc mediante μtC]

AMETRANO, GIANLUCA;RICCITIELLO, FRANCESCO;SIMEONE, MICHELE
2013

Abstract

Cleaning and shaping are important section for the root canal treatment. A number of different methodologies have been developed to overcome these problems, including the introduction of rotary instruments nickel-titanium (NiTi). In endodontics NiTi have been shown to significantly reduce procedural errors compared to manual techniques of instrumentation. The efficiency of files is related to many factor. Although previous investigations that have used μCT analysis were hampered by insufficient resolution or projection incorrect. The new generation of μCT performance best offer, as micron resolution and accurate measurement software for evaluating the accurate anatomy of the root canal. The aim the paper was to evaluate the efficiency of Reciproc files in root canal treatment, evaluated before and after instrumentation by using μ-CT analysis
2013
μcT analysis of mandibular molars before and after instrumentation by Reciproc files [Analisi anatomiche di molari mandibolari pre- e post-strumentazione con Reciproc mediante μtC] / Ametrano, Gianluca; Riccitiello, Francesco; Amato, M.; Formisano, A.; Muto, M; Grassi, R.; Valletta, A.; Simeone, Michele. - In: RECENTI PROGRESSI IN MEDICINA. - ISSN 0034-1193. - 104:7(2013), pp. 420-424. [10.1701/1315.14589]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/564322
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 10
  • ???jsp.display-item.citation.isi??? ND
social impact