Recent seismic events have clearly confirmed the vulnerability of existing reinforced concrete (RC) structures. In particular, field observation of structures damaged by L’Aquila earthquake strongly confirmed that premature failure of partially confined (i.e. exterior) beam-column joints was one of the main causes limiting the global structural seismic capacity. Poor attention to details and a lack of adequate transverse reinforcement typically lead to premature brittle shear failure of joints. To provide support to practitioners involved in the L’Aquila reconstruction process, a proper guideline which illustrates the design of local retrofit interventions on structural and non structural elements has been edited by the Italian Civil Protection Department (DPC) and the Laboratories University Network of Seismic Engineering (ReLUIS). In particular, a viable FRP strengthening strategy to increase the seismic performances of partially confined joints (design procedure and installation steps) is widely discussed and presented in the document. To validate the strengthening system recommended in this guideline, an experimental program has been carried out on as-built and FRP strengthened full scale corner RC joints (T shaped joints). After presenting the main guideline recommendations for local strengthening of existing structures, the paper focuses on the experimental program activity; in particular, the specimen design strategy and test setup definition as well as the comparative analysis of the behavior of tested joints.

FRP Local Retrofit of Non-Conforming RC Beam-Column Joints / Prota, Andrea; DI LUDOVICO, Marco; Balsamo, Alberto; C., Moroni; Dolce, Mauro; Manfredi, Gaetano. - 26:(2014), pp. 243-260. [10.1007/978-3-319-00458-7_14]

FRP Local Retrofit of Non-Conforming RC Beam-Column Joints

PROTA, ANDREA;DI LUDOVICO, MARCO;BALSAMO, ALBERTO;DOLCE, MAURO;MANFREDI, GAETANO
2014

Abstract

Recent seismic events have clearly confirmed the vulnerability of existing reinforced concrete (RC) structures. In particular, field observation of structures damaged by L’Aquila earthquake strongly confirmed that premature failure of partially confined (i.e. exterior) beam-column joints was one of the main causes limiting the global structural seismic capacity. Poor attention to details and a lack of adequate transverse reinforcement typically lead to premature brittle shear failure of joints. To provide support to practitioners involved in the L’Aquila reconstruction process, a proper guideline which illustrates the design of local retrofit interventions on structural and non structural elements has been edited by the Italian Civil Protection Department (DPC) and the Laboratories University Network of Seismic Engineering (ReLUIS). In particular, a viable FRP strengthening strategy to increase the seismic performances of partially confined joints (design procedure and installation steps) is widely discussed and presented in the document. To validate the strengthening system recommended in this guideline, an experimental program has been carried out on as-built and FRP strengthened full scale corner RC joints (T shaped joints). After presenting the main guideline recommendations for local strengthening of existing structures, the paper focuses on the experimental program activity; in particular, the specimen design strategy and test setup definition as well as the comparative analysis of the behavior of tested joints.
2014
9783319004570
9783319004587
FRP Local Retrofit of Non-Conforming RC Beam-Column Joints / Prota, Andrea; DI LUDOVICO, Marco; Balsamo, Alberto; C., Moroni; Dolce, Mauro; Manfredi, Gaetano. - 26:(2014), pp. 243-260. [10.1007/978-3-319-00458-7_14]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/564417
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? ND
social impact