This paper provides a methodology for a thorough technical comparison between traditional three-phase ac lines, on the one hand, and possible (in some cases unconventional) alternative solutions that include HVDC lines, four-phase ac lines, and combined ac-dc lines, on the other. The comparison is based on the loadability curves, which are calculated here for all of the considered lines taking into account thermal limits, voltage drop, power losses, and - when feasible - steady-state and transient stability. The focus is on four-phase ac and combined ac-dc lines, for which the loadability curves are derived for the first time, whereas the loadability curves of three-phase ac lines - well-known in the literature - are derived and used here just as the natural reference for the comparison. Due to the great deal of theoretical and numerical developments, the study is split in two. Part I analyzes single-circuit lines of comparable loadability at the thermal limit (three phase, four phase, and monopolar HVDC). Part II broadens the analysis to double-circuit lines of comparable loadability at the thermal limit (three-phase, bipolar HVDC, and combined ac-dc) and performs an overall comparison among the different systems in single-circuit and double-circuit configuration.

The Loadability of overhead transmission lines - Part I: Analysis of single circuits / Lauria, Davide; G., Mazzanti; S., Quaia. - In: IEEE TRANSACTIONS ON POWER DELIVERY. - ISSN 0885-8977. - 29:1(2014), pp. 29-37. [10.1109/TPWRD.2013.2279609]

The Loadability of overhead transmission lines - Part I: Analysis of single circuits

LAURIA, DAVIDE;
2014

Abstract

This paper provides a methodology for a thorough technical comparison between traditional three-phase ac lines, on the one hand, and possible (in some cases unconventional) alternative solutions that include HVDC lines, four-phase ac lines, and combined ac-dc lines, on the other. The comparison is based on the loadability curves, which are calculated here for all of the considered lines taking into account thermal limits, voltage drop, power losses, and - when feasible - steady-state and transient stability. The focus is on four-phase ac and combined ac-dc lines, for which the loadability curves are derived for the first time, whereas the loadability curves of three-phase ac lines - well-known in the literature - are derived and used here just as the natural reference for the comparison. Due to the great deal of theoretical and numerical developments, the study is split in two. Part I analyzes single-circuit lines of comparable loadability at the thermal limit (three phase, four phase, and monopolar HVDC). Part II broadens the analysis to double-circuit lines of comparable loadability at the thermal limit (three-phase, bipolar HVDC, and combined ac-dc) and performs an overall comparison among the different systems in single-circuit and double-circuit configuration.
2014
The Loadability of overhead transmission lines - Part I: Analysis of single circuits / Lauria, Davide; G., Mazzanti; S., Quaia. - In: IEEE TRANSACTIONS ON POWER DELIVERY. - ISSN 0885-8977. - 29:1(2014), pp. 29-37. [10.1109/TPWRD.2013.2279609]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/573305
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 29
  • ???jsp.display-item.citation.isi??? 28
social impact