The seismic behaviour of sheathed cold-formed steel (SCFS) structures is characterized by the lateral response of shear walls. Basically, if cold-formed steel (CFS) structures are designed according to the “sheathing-design” methodology, then the seismic behaviour of shear walls is strongly influenced by the sheathing-to-frame connections response, characterized by a remarkable nonlinear response and a strong pinching of hysteresis loops. In this paper the results of an extensive parametric non linear dynamic analysis, carried out on one story buildings by means of incremental dynamic analysis (IDA), using an ad hoc model of the hysteresis response of SCFS shear walls, are presented. An extended number of wall configurations has been considered investigating several parameters such as sheathing panel typology, wall geometry, external screw spacing, seismic weight and soil type. Based on IDA results, three behaviour factors have been defined, which take into account overstrength, ductility and both overstrength and ductility, respectively.

Behaviour Factor Evaluation of Sheathed Cold-Formed Steel Structures / Fiorino, Luigi; Landolfo, Raffaele; Iuorio, Ornella. - In: ADVANCED STEEL CONSTRUCTION. - ISSN 1816-112X. - 9:1(2013), pp. 26-40.

Behaviour Factor Evaluation of Sheathed Cold-Formed Steel Structures

FIORINO, Luigi;LANDOLFO, RAFFAELE;IUORIO, Ornella
2013

Abstract

The seismic behaviour of sheathed cold-formed steel (SCFS) structures is characterized by the lateral response of shear walls. Basically, if cold-formed steel (CFS) structures are designed according to the “sheathing-design” methodology, then the seismic behaviour of shear walls is strongly influenced by the sheathing-to-frame connections response, characterized by a remarkable nonlinear response and a strong pinching of hysteresis loops. In this paper the results of an extensive parametric non linear dynamic analysis, carried out on one story buildings by means of incremental dynamic analysis (IDA), using an ad hoc model of the hysteresis response of SCFS shear walls, are presented. An extended number of wall configurations has been considered investigating several parameters such as sheathing panel typology, wall geometry, external screw spacing, seismic weight and soil type. Based on IDA results, three behaviour factors have been defined, which take into account overstrength, ductility and both overstrength and ductility, respectively.
2013
Behaviour Factor Evaluation of Sheathed Cold-Formed Steel Structures / Fiorino, Luigi; Landolfo, Raffaele; Iuorio, Ornella. - In: ADVANCED STEEL CONSTRUCTION. - ISSN 1816-112X. - 9:1(2013), pp. 26-40.
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/583040
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 9
social impact