Serial quantification of BCR-ABL1 mRNA is an important therapeutic indicator in chronic myeloid leukaemia, but there is a substantial variation in results reported by different laboratories. To improve comparability, an internationally accepted plasmid certified reference material (CRM) was developed according to ISO Guide 34:2009. Fragments of BCR-ABL1 (e14a2 mRNA fusion), BCR and GUSB transcripts were amplified and cloned into pUC18 to yield plasmid pIRMM0099. Six different linearised plasmid solutions were produced with the following copy number concentrations, assigned by digital PCR, and expanded uncertainties: 1.08±0.13 × 10 6, 1.08±0.11 × 10 5, 1.03±0.10 × 10 4, 1.02±0.09 × 10 3, 1.04±0.10 × 10 2 and 10.0±1.5 copies/μl. The certification of the material for the number of specific DNA fragments per plasmid, copy number concentration of the plasmid solutions and the assessment of inter-unit heterogeneity and stability were performed according to ISO Guide 35:2006. Two suitability studies performed by 63 BCR-ABL1 testing laboratories demonstrated that this set of 6 plasmid CRMs can help to standardise a number of measured transcripts of e14a2 BCR-ABL1 and three control genes (ABL1, BCR and GUSB). The set of six plasmid CRMs is distributed worldwide by the Institute for Reference Materials and Measurements (Belgium) and its authorised distributors (https://ec.europa.eu/jrc/en/reference-materials/catalogue/; CRM code ERM-AD623a-f).

A certified plasmid reference material for the standardisation of BCR-ABL1 mRNA quantification by real-time quantitative PCR / White, H; Deprez, L; Corbisier, P; Hall, V; Lin, F; Mazoua, S; Trapmann, S; Aggerholm, A; Andrikovics, H; Akiki, S; Barbany, G; Boeckx, N; Bench, A; Catherwood, M; Cayuela, Jm; Chudleigh, S; Clench, T; Colomer, D; Daraio, F; Dulucq, S; Farrugia, J; Fletcher, L; Foroni, L; Ganderton, R; Gerrard, G; Gineikienė, E; Hayette, S; El Housni, H; Izzo, Barbara; Jansson, M; Johnels, P; Jurcek, T; Kairisto, V; Kizilors, A; Kim, Dw; Lange, T; Lion, T; Polakova, Km; Martinelli, G; Mccarron, S; Merle, Pa; Milner, B; Mitterbauer Hohendanner, G; Nagar, M; Nickless, G; Nomdedéu, J; Nymoen, Da; Leibundgut, Eo; Ozbek, U; Pajič, T; Pfeifer, H; Preudhomme, C; Raudsepp, K; Romeo, G; Sacha, T; Talmaci, R; Touloumenidou, T; Van der Velden, Vh; Waits, P; Wang, L; Wilkinson, E; Wilson, G; Wren, D; Zadro, R; Ziermann, J; Zoi, K; Müller, Mc; Hochhaus, A; Schimmel, H; Cross, Nc; Emons, H.. - In: LEUKEMIA. - ISSN 0887-6924. - 29:2(2015), pp. 369-376. [10.1038/leu.2014.217]

A certified plasmid reference material for the standardisation of BCR-ABL1 mRNA quantification by real-time quantitative PCR

IZZO, BARBARA;
2015

Abstract

Serial quantification of BCR-ABL1 mRNA is an important therapeutic indicator in chronic myeloid leukaemia, but there is a substantial variation in results reported by different laboratories. To improve comparability, an internationally accepted plasmid certified reference material (CRM) was developed according to ISO Guide 34:2009. Fragments of BCR-ABL1 (e14a2 mRNA fusion), BCR and GUSB transcripts were amplified and cloned into pUC18 to yield plasmid pIRMM0099. Six different linearised plasmid solutions were produced with the following copy number concentrations, assigned by digital PCR, and expanded uncertainties: 1.08±0.13 × 10 6, 1.08±0.11 × 10 5, 1.03±0.10 × 10 4, 1.02±0.09 × 10 3, 1.04±0.10 × 10 2 and 10.0±1.5 copies/μl. The certification of the material for the number of specific DNA fragments per plasmid, copy number concentration of the plasmid solutions and the assessment of inter-unit heterogeneity and stability were performed according to ISO Guide 35:2006. Two suitability studies performed by 63 BCR-ABL1 testing laboratories demonstrated that this set of 6 plasmid CRMs can help to standardise a number of measured transcripts of e14a2 BCR-ABL1 and three control genes (ABL1, BCR and GUSB). The set of six plasmid CRMs is distributed worldwide by the Institute for Reference Materials and Measurements (Belgium) and its authorised distributors (https://ec.europa.eu/jrc/en/reference-materials/catalogue/; CRM code ERM-AD623a-f).
2015
A certified plasmid reference material for the standardisation of BCR-ABL1 mRNA quantification by real-time quantitative PCR / White, H; Deprez, L; Corbisier, P; Hall, V; Lin, F; Mazoua, S; Trapmann, S; Aggerholm, A; Andrikovics, H; Akiki, S; Barbany, G; Boeckx, N; Bench, A; Catherwood, M; Cayuela, Jm; Chudleigh, S; Clench, T; Colomer, D; Daraio, F; Dulucq, S; Farrugia, J; Fletcher, L; Foroni, L; Ganderton, R; Gerrard, G; Gineikienė, E; Hayette, S; El Housni, H; Izzo, Barbara; Jansson, M; Johnels, P; Jurcek, T; Kairisto, V; Kizilors, A; Kim, Dw; Lange, T; Lion, T; Polakova, Km; Martinelli, G; Mccarron, S; Merle, Pa; Milner, B; Mitterbauer Hohendanner, G; Nagar, M; Nickless, G; Nomdedéu, J; Nymoen, Da; Leibundgut, Eo; Ozbek, U; Pajič, T; Pfeifer, H; Preudhomme, C; Raudsepp, K; Romeo, G; Sacha, T; Talmaci, R; Touloumenidou, T; Van der Velden, Vh; Waits, P; Wang, L; Wilkinson, E; Wilson, G; Wren, D; Zadro, R; Ziermann, J; Zoi, K; Müller, Mc; Hochhaus, A; Schimmel, H; Cross, Nc; Emons, H.. - In: LEUKEMIA. - ISSN 0887-6924. - 29:2(2015), pp. 369-376. [10.1038/leu.2014.217]
File in questo prodotto:
File Dimensione Formato  
leu2014217a.pdf

solo utenti autorizzati

Tipologia: Documento in Post-print
Licenza: Accesso privato/ristretto
Dimensione 771.95 kB
Formato Adobe PDF
771.95 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/585396
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 75
  • ???jsp.display-item.citation.isi??? 62
social impact