In this experimental study the effects of unheated auxiliary plate positions along the centerline of a vertical channel on combined natural convective in air and radiative heat transfer are investigated. The vertical channel is symmetrically heated and a uniform heat flux along the principal walls of the channel is assumed. Comparisons between experimental data carried out from different positions of the auxiliary plate and two surfaces emissivity values are given in terms of heated wall temperatures and radiative heat transfer. Average Nusselt numbers by means of experimental data are evaluated. Results are given for different thermal and geometrical dimensionless parameters. Results show that the lowest maximum channel wall temperatures are attained for the auxiliary plate placed at the channel exit for high channel Rayleigh numbers and heat flux values. Correlations for average Nusselt numbers, global average Nusselt numbers and dimensionless maximum wall temperatures in terms of channel Rayleigh numbers and auxiliary plate-to-channel height ratio, h/L, are evaluated in the ranges: 20 < Ra′ < 1.5 × 105, 22 < Ra′∗ < 1.7 × 105 and 0 ≤ h/L ≤ 0.5 for inlet and outlet positions and walls emissivity equal to 0.9. The proposed correlations are in good agreement with correlation for simple channel

Radiation effects on natural convection in a vertical channel with an auxiliary plate / Andreozzi, Assunta; Manca, O.. - In: INTERNATIONAL JOURNAL OF THERMAL SCIENCES. - ISSN 1290-0729. - 97:(2015), pp. 41-55. [10.1016/j.ijthermalsci.2015.05.013]

Radiation effects on natural convection in a vertical channel with an auxiliary plate

ANDREOZZI, ASSUNTA
;
2015

Abstract

In this experimental study the effects of unheated auxiliary plate positions along the centerline of a vertical channel on combined natural convective in air and radiative heat transfer are investigated. The vertical channel is symmetrically heated and a uniform heat flux along the principal walls of the channel is assumed. Comparisons between experimental data carried out from different positions of the auxiliary plate and two surfaces emissivity values are given in terms of heated wall temperatures and radiative heat transfer. Average Nusselt numbers by means of experimental data are evaluated. Results are given for different thermal and geometrical dimensionless parameters. Results show that the lowest maximum channel wall temperatures are attained for the auxiliary plate placed at the channel exit for high channel Rayleigh numbers and heat flux values. Correlations for average Nusselt numbers, global average Nusselt numbers and dimensionless maximum wall temperatures in terms of channel Rayleigh numbers and auxiliary plate-to-channel height ratio, h/L, are evaluated in the ranges: 20 < Ra′ < 1.5 × 105, 22 < Ra′∗ < 1.7 × 105 and 0 ≤ h/L ≤ 0.5 for inlet and outlet positions and walls emissivity equal to 0.9. The proposed correlations are in good agreement with correlation for simple channel
2015
Radiation effects on natural convection in a vertical channel with an auxiliary plate / Andreozzi, Assunta; Manca, O.. - In: INTERNATIONAL JOURNAL OF THERMAL SCIENCES. - ISSN 1290-0729. - 97:(2015), pp. 41-55. [10.1016/j.ijthermalsci.2015.05.013]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/635518
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 11
social impact