A formulation for limit analysis of three-dimensional masonry structures modelled as rigid block assemblages is presented. A concave contact model is adopted for interfaces, using contact points located at the corners of the interface to represent interactions. A no-tension and non-associative frictional behaviour with limited compressive strength is considered for joints. The limit analysis problem is formulated as a second order cone programming problem (SOCP) and an iterative procedure is proposed to model crushing failure and to take into account non-associative frictional behaviour. Applications to numerical case studies are presented for validation. Finally, the accuracy and the computational efficiency of the proposed formulation are evaluated by a comparison with the results of a full scale experimental sub-assemblage of a masonry pier-spandrel system.
An efficient solution procedure for crushing failure in 3D limit analysis of masonry block structures with non-associative frictional joints / Portioli, FRANCESCO PAOLO ANTONIO; Casapulla, Claudia; Cascini, Lucrezia. - In: INTERNATIONAL JOURNAL OF SOLIDS AND STRUCTURES. - ISSN 0020-7683. - 69-70:(2015), pp. 252-266. [10.1016/j.ijsolstr.2015.05.025]
An efficient solution procedure for crushing failure in 3D limit analysis of masonry block structures with non-associative frictional joints
PORTIOLI, FRANCESCO PAOLO ANTONIO;CASAPULLA, CLAUDIA;CASCINI, LUCREZIA
2015
Abstract
A formulation for limit analysis of three-dimensional masonry structures modelled as rigid block assemblages is presented. A concave contact model is adopted for interfaces, using contact points located at the corners of the interface to represent interactions. A no-tension and non-associative frictional behaviour with limited compressive strength is considered for joints. The limit analysis problem is formulated as a second order cone programming problem (SOCP) and an iterative procedure is proposed to model crushing failure and to take into account non-associative frictional behaviour. Applications to numerical case studies are presented for validation. Finally, the accuracy and the computational efficiency of the proposed formulation are evaluated by a comparison with the results of a full scale experimental sub-assemblage of a masonry pier-spandrel system.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.