The relative vibrations of two small frames with different stiffness, subjected to the same oscillating excitation coming from their base platform, were investigated. The effects of the innovative coupling of standard passive attenuation and time variation of magnetic forces (self-produced by the vibration itself) were investigated. The first experimental tests demonstrate that the amplitude of relative vibration can be easily decreased up to 75% without requiring external energy. In perspective, by varying the attenuator shape and power, it is possible to use it in all the cases in which it is necessary to reduce the vibrations of a breakable or unstable structure inside a building accidentally exposed to vibration, such as a rotor inside a frame or a shelf in a museum room.

Relative vibration attenuation by means of self-active devices constituted by permanent magnets separated by silicone layers / Ricciardi, Enrico; Ausanio, Giovanni; Iannotti, Vincenzo; Pasquino, Vittorio; Silvestri, Brigida; Lanotte, Luciano. - In: STRUCTURAL CONTROL & HEALTH MONITORING. - ISSN 1545-2255. - 24:5(2017), pp. e1914-1-e1914-9. [10.1002/stc.1914]

Relative vibration attenuation by means of self-active devices constituted by permanent magnets separated by silicone layers

RICCIARDI, ENRICO;AUSANIO, GIOVANNI;IANNOTTI, VINCENZO;PASQUINO, VITTORIO;SILVESTRI, BRIGIDA;LANOTTE, LUCIANO
2017

Abstract

The relative vibrations of two small frames with different stiffness, subjected to the same oscillating excitation coming from their base platform, were investigated. The effects of the innovative coupling of standard passive attenuation and time variation of magnetic forces (self-produced by the vibration itself) were investigated. The first experimental tests demonstrate that the amplitude of relative vibration can be easily decreased up to 75% without requiring external energy. In perspective, by varying the attenuator shape and power, it is possible to use it in all the cases in which it is necessary to reduce the vibrations of a breakable or unstable structure inside a building accidentally exposed to vibration, such as a rotor inside a frame or a shelf in a museum room.
2017
Relative vibration attenuation by means of self-active devices constituted by permanent magnets separated by silicone layers / Ricciardi, Enrico; Ausanio, Giovanni; Iannotti, Vincenzo; Pasquino, Vittorio; Silvestri, Brigida; Lanotte, Luciano. - In: STRUCTURAL CONTROL & HEALTH MONITORING. - ISSN 1545-2255. - 24:5(2017), pp. e1914-1-e1914-9. [10.1002/stc.1914]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/656698
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact