Synthetic grafts are often satisfactory employed in cardiac and vascular surgery, including expanded poly(ethylene terephthalate) or expanded poly(tetrafluoroethylene). However, accumulating evidences suggest the emergence of worrisome issues concerning the long-term fate of prosthetic grafts as large vessel replacement. Disadvantages related to the use of synthetic grafts can be traced in their inability of mimicking the elasto-mechanical characteristics of the native vascular tissue, local suture overstress leading to several prosthesis-related complications and retrograde deleterious effects on valve competence, cardiac function and perfusion. Motivated by this, in the present work it is analyzed – by means of both elemental biomechanical paradigms and more accurate in silico Finite Element simulations – the physical interaction among aorta, autograft and widely adopted synthetic (Dacron) prostheses utilized in transposition of pulmonary artery, highlighting the crucial role played by somehow unexpected stress fields kindled in the vessel walls and around suture regions, which could be traced as prodromal to the triggering of anomalous remodelling processes and alterations of needed surgical outcomes. Theoretical results are finally compared with histological and surgical data related to a significant experimental animal campaign conducted by performing pulmonary artery transpositions in 30 two-month old growing lambs, followed up during growth for six months. The in vivo observations demonstrate the effectiveness of the proposed biomechanical hypothesis and open the way for possible engineering-guided strategies to support and optimize surgical procedures.

Compliance mismatch and compressive wall stresses drive anomalous remodelling of pulmonary trunks reinforced with Dacron grafts / Nappi, Francesco; Carotenuto, ANGELO ROSARIO; Cutolo, Arsenio; Fouret, Pierre; Acar, Christophe; Chachques, Juan Carlos; Fraldi, Massimiliano. - In: JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS. - ISSN 1751-6161. - 63:(2016), pp. 287-302. [10.1016/j.jmbbm.2016.06.023]

Compliance mismatch and compressive wall stresses drive anomalous remodelling of pulmonary trunks reinforced with Dacron grafts

CAROTENUTO, ANGELO ROSARIO;CUTOLO, ARSENIO;FRALDI, MASSIMILIANO
2016

Abstract

Synthetic grafts are often satisfactory employed in cardiac and vascular surgery, including expanded poly(ethylene terephthalate) or expanded poly(tetrafluoroethylene). However, accumulating evidences suggest the emergence of worrisome issues concerning the long-term fate of prosthetic grafts as large vessel replacement. Disadvantages related to the use of synthetic grafts can be traced in their inability of mimicking the elasto-mechanical characteristics of the native vascular tissue, local suture overstress leading to several prosthesis-related complications and retrograde deleterious effects on valve competence, cardiac function and perfusion. Motivated by this, in the present work it is analyzed – by means of both elemental biomechanical paradigms and more accurate in silico Finite Element simulations – the physical interaction among aorta, autograft and widely adopted synthetic (Dacron) prostheses utilized in transposition of pulmonary artery, highlighting the crucial role played by somehow unexpected stress fields kindled in the vessel walls and around suture regions, which could be traced as prodromal to the triggering of anomalous remodelling processes and alterations of needed surgical outcomes. Theoretical results are finally compared with histological and surgical data related to a significant experimental animal campaign conducted by performing pulmonary artery transpositions in 30 two-month old growing lambs, followed up during growth for six months. The in vivo observations demonstrate the effectiveness of the proposed biomechanical hypothesis and open the way for possible engineering-guided strategies to support and optimize surgical procedures.
2016
Compliance mismatch and compressive wall stresses drive anomalous remodelling of pulmonary trunks reinforced with Dacron grafts / Nappi, Francesco; Carotenuto, ANGELO ROSARIO; Cutolo, Arsenio; Fouret, Pierre; Acar, Christophe; Chachques, Juan Carlos; Fraldi, Massimiliano. - In: JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS. - ISSN 1751-6161. - 63:(2016), pp. 287-302. [10.1016/j.jmbbm.2016.06.023]
File in questo prodotto:
File Dimensione Formato  
JMBBM_2016_Compliance mismatch_Dacron_.pdf

solo utenti autorizzati

Tipologia: Documento in Post-print
Licenza: Accesso privato/ristretto
Dimensione 802.76 kB
Formato Adobe PDF
802.76 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/659050
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 42
  • ???jsp.display-item.citation.isi??? 40
social impact