This work aims to present the results of an energetic and economic analysis of a biomass fueled CCHP system operating according to different design configurations. The investigated system consists of a biomass-fueled cogeneration unit, an absorption chiller, a thermal energy storage system and a cold one, providing electricity, heat and cooling to an Italian cluster of buildings. For each simulated configuration, the feasible investment cost of the CHP unit is evaluated considering the economic savings obtained with respect to separate generation of electricity, heat and cooling. The best configuration from the economic point of view is indicated, and the incidence of the variation of the absorption chiller and storage systems sizes on the feasible investment cost of the CHP unit is evaluated and discussed as well. Results indicate that the most influencing parameter is represented by the absorption chiller power.

Analysis of a biomass-fired CCHP system considering different design configurations / Caliano, Martina; Bianco, Nicola; Graditi, Giorgio; Mongibello, Luigi. - In: ENERGY PROCEDIA. - ISSN 1876-6102. - (2017).

Analysis of a biomass-fired CCHP system considering different design configurations

CALIANO, MARTINA;BIANCO, NICOLA;
2017

Abstract

This work aims to present the results of an energetic and economic analysis of a biomass fueled CCHP system operating according to different design configurations. The investigated system consists of a biomass-fueled cogeneration unit, an absorption chiller, a thermal energy storage system and a cold one, providing electricity, heat and cooling to an Italian cluster of buildings. For each simulated configuration, the feasible investment cost of the CHP unit is evaluated considering the economic savings obtained with respect to separate generation of electricity, heat and cooling. The best configuration from the economic point of view is indicated, and the incidence of the variation of the absorption chiller and storage systems sizes on the feasible investment cost of the CHP unit is evaluated and discussed as well. Results indicate that the most influencing parameter is represented by the absorption chiller power.
2017
Analysis of a biomass-fired CCHP system considering different design configurations / Caliano, Martina; Bianco, Nicola; Graditi, Giorgio; Mongibello, Luigi. - In: ENERGY PROCEDIA. - ISSN 1876-6102. - (2017).
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/662730
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 9
  • ???jsp.display-item.citation.isi??? 8
social impact