The SYRMA-CT project aims to set-up the first clinical trial of phase-contrast breast Computed Tomography with synchrotron radiation at the SYRMEP beamline of Elettra, the Italian synchrotron light source. The challenge in a dedicated breast CT is to match a high spatial resolution with a low dose level. In order to fulfil these requirements, the SYRMA-CT project uses a large area CdTe single photon counting detector (Pixirad-8), simultaneous algebraic reconstruction technique (SART) and phase retrieval pre-processing. This work investigates the imaging performances of the system in a continuous acquisition mode and with a low dose level towards the clinical application. A custom test object and a large surgical sample have been studied.

Imaging study of a phase-sensitive breast-CT system in continuous acquisition mode / Delogu, P.; Golosio, B.; Fedon, C.; Arfelli, F.; Bellazzini, R.; Brez, A.; Brun, F.; DI LILLO, Francesca; Dreossi, D.; Mettivier, Giovanni; Minuti, M.; Oliva, P.; Pichera, M.; Rigon, L.; Russo, Paolo; Sarno, Antonio; Spandre, G.; Tromba, G.; Longo, R.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 12:01(2017), pp. C01016-C01016. [10.1088/1748-0221/12/01/C01016]

Imaging study of a phase-sensitive breast-CT system in continuous acquisition mode

DI LILLO, FRANCESCA;METTIVIER, GIOVANNI;RUSSO, PAOLO;SARNO, ANTONIO;
2017

Abstract

The SYRMA-CT project aims to set-up the first clinical trial of phase-contrast breast Computed Tomography with synchrotron radiation at the SYRMEP beamline of Elettra, the Italian synchrotron light source. The challenge in a dedicated breast CT is to match a high spatial resolution with a low dose level. In order to fulfil these requirements, the SYRMA-CT project uses a large area CdTe single photon counting detector (Pixirad-8), simultaneous algebraic reconstruction technique (SART) and phase retrieval pre-processing. This work investigates the imaging performances of the system in a continuous acquisition mode and with a low dose level towards the clinical application. A custom test object and a large surgical sample have been studied.
2017
Imaging study of a phase-sensitive breast-CT system in continuous acquisition mode / Delogu, P.; Golosio, B.; Fedon, C.; Arfelli, F.; Bellazzini, R.; Brez, A.; Brun, F.; DI LILLO, Francesca; Dreossi, D.; Mettivier, Giovanni; Minuti, M.; Oliva, P.; Pichera, M.; Rigon, L.; Russo, Paolo; Sarno, Antonio; Spandre, G.; Tromba, G.; Longo, R.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 12:01(2017), pp. C01016-C01016. [10.1088/1748-0221/12/01/C01016]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/666501
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 30
  • ???jsp.display-item.citation.isi??? 30
social impact