The recent scandal of poly implant prostheses (PIP), which were found in some cases to be made of non-medical grade silicone (as reported by the European Scientific Committee on Emerging and Newly Identified Health Risks), had a great social impact. Thousands of patients asked for implant removal with significant costs for public health care systems. We analysed, by a multidisciplinary approach, sixteen different breast implants after explantation by using several analytical and structural techniques, such as Fourier Transform infrared spectroscopy (FT-IR), mass spectrometry equipped by ion coupled plasma (ICP-MS), gas-chromatography (GC-MS), and tensile testing. Traces of organic (fatty acid) and inorganic (Fe, Cr, Pt, Na, and other metals) substances were found in all samples, and, even if these values are under danger threshold levels, our study results highlight the possibility of bioaccumulation and tissue contamination, implying the need for continuous medical surveillance and monitoring of material aging
Chemical and Structural Characterization of Several Mid-Term Explanted Breast Prostheses / Amoresano, Angela; DE STEFANO, Luca; Rea, Ilaria; Pane, Federica; Birolo, Leila; Schonauer, Fabrizio. - In: MATERIALS. - ISSN 1996-1944. - 9:8(2016), pp. 678-689. [10.3390/ma9080678]
Chemical and Structural Characterization of Several Mid-Term Explanted Breast Prostheses
AMORESANO, ANGELA;DE STEFANO, Luca;REA, ILARIA;BIROLO, LEILA;SCHONAUER, FABRIZIO
2016
Abstract
The recent scandal of poly implant prostheses (PIP), which were found in some cases to be made of non-medical grade silicone (as reported by the European Scientific Committee on Emerging and Newly Identified Health Risks), had a great social impact. Thousands of patients asked for implant removal with significant costs for public health care systems. We analysed, by a multidisciplinary approach, sixteen different breast implants after explantation by using several analytical and structural techniques, such as Fourier Transform infrared spectroscopy (FT-IR), mass spectrometry equipped by ion coupled plasma (ICP-MS), gas-chromatography (GC-MS), and tensile testing. Traces of organic (fatty acid) and inorganic (Fe, Cr, Pt, Na, and other metals) substances were found in all samples, and, even if these values are under danger threshold levels, our study results highlight the possibility of bioaccumulation and tissue contamination, implying the need for continuous medical surveillance and monitoring of material agingFile | Dimensione | Formato | |
---|---|---|---|
Chemical and structural Characterization.pdf
accesso aperto
Tipologia:
Versione Editoriale (PDF)
Licenza:
Copyright dell'editore
Dimensione
969.05 kB
Formato
Adobe PDF
|
969.05 kB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.