The effect of strut shape on convection heat transfer and pressure drop in open-cell metal foams has been investigated numerically in this paper by introducing the foam shape factor, a parameter that characterizes the shape of the strut. The analysis has been carried out both on real and ideal foams. The geometry of three 40 PPI real foams, with 0.87, 0.94 and 0.96 average measured porosities, was determined with CT-tomography and a morphological analysis of the CT data was carried out. The geometry of the ideal foams, based on the Kelvin foam, with the same PPI and porosities as those of the real foams, was generated with the free-to-use software Surface Evolver, building up foams with different strut shapes. Governing equations have been solved with a finite element scheme, assuming a uniform heat flux condition at the solid/fluid boundary of the foam. Results are presented in terms of convection heat transfer coefficients and pressure distributions as a function of strut shape parameters. The comparison between predictions for ideal and real foams, for different strut shapes, confirms that, in all cases, the closer the form of the ideal strut to that of the real strut the better the agreement among predictions.

The effect of open-cell metal foams strut shape on convection heat transfer and pressure drop / Ambrosio, Giuseppe; Bianco, Nicola; Chiu, Wilson K. S.; Iasiello, Marcello; Naso, Vincenzo; Oliviero, Maria. - In: APPLIED THERMAL ENGINEERING. - ISSN 1359-4311. - 103:(2016), pp. 333-343. [10.1016/j.applthermaleng.2016.04.085]

The effect of open-cell metal foams strut shape on convection heat transfer and pressure drop

BIANCO, NICOLA;IASIELLO, MARCELLO;
2016

Abstract

The effect of strut shape on convection heat transfer and pressure drop in open-cell metal foams has been investigated numerically in this paper by introducing the foam shape factor, a parameter that characterizes the shape of the strut. The analysis has been carried out both on real and ideal foams. The geometry of three 40 PPI real foams, with 0.87, 0.94 and 0.96 average measured porosities, was determined with CT-tomography and a morphological analysis of the CT data was carried out. The geometry of the ideal foams, based on the Kelvin foam, with the same PPI and porosities as those of the real foams, was generated with the free-to-use software Surface Evolver, building up foams with different strut shapes. Governing equations have been solved with a finite element scheme, assuming a uniform heat flux condition at the solid/fluid boundary of the foam. Results are presented in terms of convection heat transfer coefficients and pressure distributions as a function of strut shape parameters. The comparison between predictions for ideal and real foams, for different strut shapes, confirms that, in all cases, the closer the form of the ideal strut to that of the real strut the better the agreement among predictions.
2016
The effect of open-cell metal foams strut shape on convection heat transfer and pressure drop / Ambrosio, Giuseppe; Bianco, Nicola; Chiu, Wilson K. S.; Iasiello, Marcello; Naso, Vincenzo; Oliviero, Maria. - In: APPLIED THERMAL ENGINEERING. - ISSN 1359-4311. - 103:(2016), pp. 333-343. [10.1016/j.applthermaleng.2016.04.085]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/670688
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 84
  • ???jsp.display-item.citation.isi??? 78
social impact