Faecal egg counts (FECs) are used for detecting and quantifying nematode infections and are the basis for determining drug efficacy and anthelmintic resistance in faecal egg count reduction tests (FECRTs). Currently, several FEC techniques are available for detecting and quantifying eggs of sheep nematodes. A comparison of the egg counts from the FECPAK (with a minimum detection limit of 30 eggs per gram (epg)) and Mini-FLOTAC (with a minimum detection limit of 5 epg) showed better diagnostic performance with Mini-FLOTAC in terms of measurement error (level of over- or under-estimation of FEC) and precision (variability in FEC). A tendency to under-estimate FEC was observed with the FECPAK particularly at egg densities of less than 500 epg. It is concluded that Mini-FLOTAC is a reliable diagnostic tool offering reduced measurement error and a higher level of precision.

A comparison of the FECPAK and Mini-FLOTAC faecal egg counting techniques / Godber, Olivia F; Phythian, Clare J; Bosco, Antonio; Ianniello, Davide; Coles, Gerald; Rinaldi, Laura; Cringoli, Giuseppe. - In: VETERINARY PARASITOLOGY. - ISSN 0304-4017. - 207:3-4(2015), pp. 342-345. [10.1016/j.vetpar.2014.12.029]

A comparison of the FECPAK and Mini-FLOTAC faecal egg counting techniques

BOSCO, ANTONIO;IANNIELLO, DAVIDE;RINALDI, LAURA
Penultimo
;
CRINGOLI, GIUSEPPE
Ultimo
2015

Abstract

Faecal egg counts (FECs) are used for detecting and quantifying nematode infections and are the basis for determining drug efficacy and anthelmintic resistance in faecal egg count reduction tests (FECRTs). Currently, several FEC techniques are available for detecting and quantifying eggs of sheep nematodes. A comparison of the egg counts from the FECPAK (with a minimum detection limit of 30 eggs per gram (epg)) and Mini-FLOTAC (with a minimum detection limit of 5 epg) showed better diagnostic performance with Mini-FLOTAC in terms of measurement error (level of over- or under-estimation of FEC) and precision (variability in FEC). A tendency to under-estimate FEC was observed with the FECPAK particularly at egg densities of less than 500 epg. It is concluded that Mini-FLOTAC is a reliable diagnostic tool offering reduced measurement error and a higher level of precision.
2015
A comparison of the FECPAK and Mini-FLOTAC faecal egg counting techniques / Godber, Olivia F; Phythian, Clare J; Bosco, Antonio; Ianniello, Davide; Coles, Gerald; Rinaldi, Laura; Cringoli, Giuseppe. - In: VETERINARY PARASITOLOGY. - ISSN 0304-4017. - 207:3-4(2015), pp. 342-345. [10.1016/j.vetpar.2014.12.029]
File in questo prodotto:
File Dimensione Formato  
656 - Godber et al., 2015.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: Accesso privato/ristretto
Dimensione 184.95 kB
Formato Adobe PDF
184.95 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/670816
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 34
  • ???jsp.display-item.citation.isi??? 33
social impact