During the last years, the research interest in assessing noise and vibration optimization has been addressed on different control typologies, based both on active and passive architectures. Within the paper, some preliminary activities aimed at the realization of a structurally simple, cheap and easily replaceable active control systems is discussed. Under these premises, the paper deals with the assessment of an Enhanced Synchronized Shunted Switch Architecture (SSSA) control architecture, based upon the use of piezoelectric devices, specifically optimized for a cantilver beam structure. Main activities regarded the control system set up and optimization, both under the electronic than the piezo location points of view, and control results under deterministic and stochastic forcing actions. Experimental results have been compared with the numerical one as well as a comparison between the SSSA approach and other active control architectures has been also presented and discussed. Results have shown a good performances of the proposed approach that present also a relative easy implementation if compared with already assessed control technologies.

A modified Shunted Switch Architecture (SSSA) for active vibration control / Viscardi, Massimo; Arena, Maurizio; Ciminello, Monica. - 10595:(2018), pp. 6-15. (Intervento presentato al convegno Active and Passive Smart Structures and Integrated Systems XII 2018 tenutosi a usa nel 2018) [10.1117/12.2296421].

A modified Shunted Switch Architecture (SSSA) for active vibration control

Viscardi, Massimo;Arena, Maurizio;
2018

Abstract

During the last years, the research interest in assessing noise and vibration optimization has been addressed on different control typologies, based both on active and passive architectures. Within the paper, some preliminary activities aimed at the realization of a structurally simple, cheap and easily replaceable active control systems is discussed. Under these premises, the paper deals with the assessment of an Enhanced Synchronized Shunted Switch Architecture (SSSA) control architecture, based upon the use of piezoelectric devices, specifically optimized for a cantilver beam structure. Main activities regarded the control system set up and optimization, both under the electronic than the piezo location points of view, and control results under deterministic and stochastic forcing actions. Experimental results have been compared with the numerical one as well as a comparison between the SSSA approach and other active control architectures has been also presented and discussed. Results have shown a good performances of the proposed approach that present also a relative easy implementation if compared with already assessed control technologies.
2018
9781510616868
A modified Shunted Switch Architecture (SSSA) for active vibration control / Viscardi, Massimo; Arena, Maurizio; Ciminello, Monica. - 10595:(2018), pp. 6-15. (Intervento presentato al convegno Active and Passive Smart Structures and Integrated Systems XII 2018 tenutosi a usa nel 2018) [10.1117/12.2296421].
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/726674
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 0
social impact