In the Muon g-2 Experiment at Fermilab, a calibration apparatus based on a set of laser sources and a distribution system has been designed and implemented by the INFN group. The light pulses are read by specific photo-detectors, whose signals are digitized by custom electronics modules designed to match the experimental requirements. The data frames of each module are transmitted to a controller board that performs the event-building process and transfers the reconstructed data to the online farm. In this work we present the architecture and data flow of the acquisition system that depends on the laser calibration program defined inside the Laser Control board. Experimental results on the overall system performances, also including the software processes running both at controller and farm level will be described.

Muon g-2 calibration system data flow / Anastasi, A.; Anastasio, A.; Avino, S.; Bedeschi, F.; Boiano, A.; Cantatore, G.; Cauz, D.; Ceravolo, S.; Corradi, G.; Dabagov, S.; Di Falco, S.; Di Meo, P.; Donati, S.; Driutti, A.; Di Sciascio, G.; Di Stefano, R.; Escalante, O.; Ferrari, C.; Fioretti, A.; Gabbanini, C.; Gagliardi, G.; Gioiosa, A.; Hampai, D.; Iacovacci, M.; Incagli, M.; Karuza, M.; Lusiani, A.; Marignetti, F.; Mastroianni, S.; Moricciani, D.; Nath, A.; Pauletta, G.; Piacentino, G. M.; Raha, N.; Santi, L.; Smith, M. W.; Venanzoni, G.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 936:(2019), pp. 335-336. [10.1016/j.nima.2018.10.005]

Muon g-2 calibration system data flow

Escalante, O.;Iacovacci, M.;Marignetti, F.;Nath, A.;
2019

Abstract

In the Muon g-2 Experiment at Fermilab, a calibration apparatus based on a set of laser sources and a distribution system has been designed and implemented by the INFN group. The light pulses are read by specific photo-detectors, whose signals are digitized by custom electronics modules designed to match the experimental requirements. The data frames of each module are transmitted to a controller board that performs the event-building process and transfers the reconstructed data to the online farm. In this work we present the architecture and data flow of the acquisition system that depends on the laser calibration program defined inside the Laser Control board. Experimental results on the overall system performances, also including the software processes running both at controller and farm level will be described.
2019
Muon g-2 calibration system data flow / Anastasi, A.; Anastasio, A.; Avino, S.; Bedeschi, F.; Boiano, A.; Cantatore, G.; Cauz, D.; Ceravolo, S.; Corradi, G.; Dabagov, S.; Di Falco, S.; Di Meo, P.; Donati, S.; Driutti, A.; Di Sciascio, G.; Di Stefano, R.; Escalante, O.; Ferrari, C.; Fioretti, A.; Gabbanini, C.; Gagliardi, G.; Gioiosa, A.; Hampai, D.; Iacovacci, M.; Incagli, M.; Karuza, M.; Lusiani, A.; Marignetti, F.; Mastroianni, S.; Moricciani, D.; Nath, A.; Pauletta, G.; Piacentino, G. M.; Raha, N.; Santi, L.; Smith, M. W.; Venanzoni, G.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 936:(2019), pp. 335-336. [10.1016/j.nima.2018.10.005]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/727375
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact