Rationale: Thyroglobulin (Tg) is an accurate indicator of clinical outcome after total thyroidectomy in patients with differentiated thyroid carcinoma. Usually, Tg levels agree with whole body scan. However, in some patient, discordant results were found, often because of Tg immunoassay interference. Several reports indicated that 2-site immunoassay interference with heterophile antibodies (HAb) can lead to misinterpretation of the laboratory test result. Patient concerns: We report a case of a 46-year-old woman referred to our endocrine clinic for markedly increased calcitonin (CT) without the associated clinical picture. The measurement was repeated with the same patient sample on a different analytical platform and the result was an undetectable CT level. The measurement of Tg was repeated on 3 different analytical platforms using chemiluminescence and electrochemiluminescence immunoassays and the results were different on each platform. HAb blocking tubes resulted in a different level of both CT and Tg, suggesting the presence of a heterophile substance in the serum sample. Further characterization showed reactivity to several animal species antibodies and an elevated level of the rheumatoid factor (RF). Diagnoses: She was diagnosed as papillary thyroid carcinoma. Interventions: She had undergone thyroidectomy with lymph node dissection and radioactive therapy. Outcomes: She was found not to have recurrence despite a high serum Tg level. Lessons: Our report illustrates a rare case of falsely elevated tumor markers levels due to assay interference caused by RF. This finding pointed out the importance of close communication between the clinician and laboratory staff in order to bring to light discordance between laboratory test results and clinical picture and avoid unnecessary diagnostic procedures and overtreatment.

Falsely elevated thyroglobulin and calcitonin due to rheumatoid factor in non-relapsing thyroid carcinoma: A case report / Lupoli, Gelsy Arianna; Barba, Livia; Liotti, Antonietta; La Civita, Evelina; Lupoli, Roberta; Riccio, Enrico; Portella, Giuseppe; Formisano, Pietro; Beguinot, Francesco; Terracciano, Daniela. - In: MEDICINE. - ISSN 1536-5964. - 98:5(2019), p. e14178. [10.1097/MD.0000000000014178]

Falsely elevated thyroglobulin and calcitonin due to rheumatoid factor in non-relapsing thyroid carcinoma: A case report

BARBA, LIVIA;Liotti, Antonietta;Lupoli, Roberta;RICCIO, ENRICO;Portella, Giuseppe;Formisano, Pietro;Beguinot, Francesco;Terracciano, Daniela
2019

Abstract

Rationale: Thyroglobulin (Tg) is an accurate indicator of clinical outcome after total thyroidectomy in patients with differentiated thyroid carcinoma. Usually, Tg levels agree with whole body scan. However, in some patient, discordant results were found, often because of Tg immunoassay interference. Several reports indicated that 2-site immunoassay interference with heterophile antibodies (HAb) can lead to misinterpretation of the laboratory test result. Patient concerns: We report a case of a 46-year-old woman referred to our endocrine clinic for markedly increased calcitonin (CT) without the associated clinical picture. The measurement was repeated with the same patient sample on a different analytical platform and the result was an undetectable CT level. The measurement of Tg was repeated on 3 different analytical platforms using chemiluminescence and electrochemiluminescence immunoassays and the results were different on each platform. HAb blocking tubes resulted in a different level of both CT and Tg, suggesting the presence of a heterophile substance in the serum sample. Further characterization showed reactivity to several animal species antibodies and an elevated level of the rheumatoid factor (RF). Diagnoses: She was diagnosed as papillary thyroid carcinoma. Interventions: She had undergone thyroidectomy with lymph node dissection and radioactive therapy. Outcomes: She was found not to have recurrence despite a high serum Tg level. Lessons: Our report illustrates a rare case of falsely elevated tumor markers levels due to assay interference caused by RF. This finding pointed out the importance of close communication between the clinician and laboratory staff in order to bring to light discordance between laboratory test results and clinical picture and avoid unnecessary diagnostic procedures and overtreatment.
2019
Falsely elevated thyroglobulin and calcitonin due to rheumatoid factor in non-relapsing thyroid carcinoma: A case report / Lupoli, Gelsy Arianna; Barba, Livia; Liotti, Antonietta; La Civita, Evelina; Lupoli, Roberta; Riccio, Enrico; Portella, Giuseppe; Formisano, Pietro; Beguinot, Francesco; Terracciano, Daniela. - In: MEDICINE. - ISSN 1536-5964. - 98:5(2019), p. e14178. [10.1097/MD.0000000000014178]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/737355
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 11
  • ???jsp.display-item.citation.isi??? 9
social impact