The following paper presents a method to optimise a discontinuous permeable adsorptive barrier (PAB-D). This method is based on the comparison of different PAB-D configurations obtained by changing some of the main PAB-D design parameters. In particular, the well diameters, the distance between two consecutive passive wells and the distance between two consecutive well lines were varied, and a cost analysis for each configuration was carried out in order to define the best performing and most cost-effective PAB-D configuration. As a case study, a benzene-contaminated aquifer located in an urban area in the north of Naples (Italy) was considered. The PAB-D configuration with a well diameter of 0.8 m resulted the best optimised layout in terms of performance and cost-effectiveness. Moreover, in order to identify the best configuration for the remediation of the aquifer studied, a comparison with a continuous permeable adsorptive barrier (PAB-C) was added. In particular, this showed a 40% reduction of the total remediation costs by using the optimised PAB-D.

Discontinuous permeable adsorptive barrier design and cost analysis: a methodological approach to optimisation / Santonastaso, Giovanni Francesco; Bortone, Immacolata; Chianese, Simeone; DI NARDO, Armando; Di Natale, Michele; Erto, Alessandro; Karatza, Despina; Musmarra, Dino. - In: ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL. - ISSN 0944-1344. - (2017), pp. 26793-26800. [10.1007/s11356-017-0220-y]

Discontinuous permeable adsorptive barrier design and cost analysis: a methodological approach to optimisation

Bortone, Immacolata;Chianese, Simeone;DI NARDO, ARMANDO;Erto, Alessandro;Musmarra, Dino
2017

Abstract

The following paper presents a method to optimise a discontinuous permeable adsorptive barrier (PAB-D). This method is based on the comparison of different PAB-D configurations obtained by changing some of the main PAB-D design parameters. In particular, the well diameters, the distance between two consecutive passive wells and the distance between two consecutive well lines were varied, and a cost analysis for each configuration was carried out in order to define the best performing and most cost-effective PAB-D configuration. As a case study, a benzene-contaminated aquifer located in an urban area in the north of Naples (Italy) was considered. The PAB-D configuration with a well diameter of 0.8 m resulted the best optimised layout in terms of performance and cost-effectiveness. Moreover, in order to identify the best configuration for the remediation of the aquifer studied, a comparison with a continuous permeable adsorptive barrier (PAB-C) was added. In particular, this showed a 40% reduction of the total remediation costs by using the optimised PAB-D.
2017
Discontinuous permeable adsorptive barrier design and cost analysis: a methodological approach to optimisation / Santonastaso, Giovanni Francesco; Bortone, Immacolata; Chianese, Simeone; DI NARDO, Armando; Di Natale, Michele; Erto, Alessandro; Karatza, Despina; Musmarra, Dino. - In: ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH INTERNATIONAL. - ISSN 0944-1344. - (2017), pp. 26793-26800. [10.1007/s11356-017-0220-y]
File in questo prodotto:
File Dimensione Formato  
Discontinuous permeable adsorptive barrier design and cost analysis - a methodological approach to optimisation.pdf

non disponibili

Licenza: Accesso privato/ristretto
Dimensione 1.13 MB
Formato Adobe PDF
1.13 MB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/741063
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
social impact