Attenzione: i dati modificati non sono ancora stati salvati. Per confermare inserimenti o cancellazioni di voci è necessario confermare con il tasto SALVA/INSERISCI in fondo alla pagina
IRIS
The need of a fs-scale pulsed, high repetition rate, X-ray source for time-resolved fine analysis of matter (spectroscopy and photon scattering) in the linear response regime is addressed by the conceptual design of a facility called MariX (Multi-disciplinary Advanced Research Infrastructure for the generation and application of X-rays) outperforming current X-ray sources for the declared scope. MariX is based on the original design of a two-pass two-way superconducting linear electron accelerator, equipped with an arc compressor, to be operated in CW mode (1 MHz). MariX provides FEL emission in the range 0.2–8 keV with photons per pulse ideally suited for photoelectric effect and inelastic X-ray scattering experiments. The accelerator complex includes an early stage that supports an advanced inverse Compton source of very high-flux hard X-rays of energies up to 180 keV that is well adapted for large area radiological imaging, realizing a broad science programme and serving a multidisciplinary user community, covering fundamental science of matter and application to life sciences, including health at preclinical and clinical level.
MariX, an advanced MHz-class repetition rate X-ray source for linear regime time-resolved spectroscopy and photon scattering / Serafini, L.; Bacci, A.; Bellandi, A.; Bertucci, M.; Bolognesi, M.; Bosotti, A.; Broggi, F.; Calandrino, R.; Camera, F.; Canella, F.; Capra, S.; Cardarelli, P.; Carrara, M.; Cassou, K.; Castoldi, A.; Castriconi, R.; Cattaneo, G. M.; Cialdi, S.; Cianchi, A.; Coluccelli, N.; Curatolo, C.; Del Vecchio, A.; Di Mitri, S.; Drebot, I.; Dupraz, K.; Esposito, A.; Faillace, L.; Ferrario, M.; Fiorini, C.; Galzerano, G.; Gambaccini, M.; Ghiringhelli, G.; Giannotti, D.; Giove, D.; Groppi, F.; Guazzoni, C.; Laporta, P.; Leoni, S.; Loria, A.; Mangili, P.; Martens, A.; Mazza, T.; Mazzotta, Z.; Meroni, C.; Mettivier, Giovanni; Michelato, P.; Monaco, L.; Morante, S.; Moretti Sala, M.; Nutarelli, D.; Olivares, S.; Onida, G.; Opromolla, M.; Pagani, C.; Paparella, R.; Paris, M. G. A.; Paroli, B.; Paternò, G.; Paulin, C.; Perini, L.; Petrarca, M.; Petrillo, V.; Pinotti, E.; Piseri, P.; Potenza, M. A. C.; Prelz, F.; Pullia, A.; Puppin, E.; Ragusa, F.; Ramponi, R.; Romè, M.; Rossetti Conti, M.; Rossi, A. R.; Rossi, L.; Ruijter, M.; Russo, Paolo; Samsam, S.; Sarno, Antonio; Sertore, D.; Sorbi, M.; Spataro, B.; Statera, M.; Stellato, F.; Suerra, E.; Tagliaferri, A.; Taibi, A.; Torri, V.; Turchetti, G.; Vaccarezza, C.; Valdagni, R.; Vanzulli, A.; Zomer, F.; Rossi, G.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 930:(2019), pp. 167-172. [10.1016/j.nima.2019.03.096]
MariX, an advanced MHz-class repetition rate X-ray source for linear regime time-resolved spectroscopy and photon scattering
The need of a fs-scale pulsed, high repetition rate, X-ray source for time-resolved fine analysis of matter (spectroscopy and photon scattering) in the linear response regime is addressed by the conceptual design of a facility called MariX (Multi-disciplinary Advanced Research Infrastructure for the generation and application of X-rays) outperforming current X-ray sources for the declared scope. MariX is based on the original design of a two-pass two-way superconducting linear electron accelerator, equipped with an arc compressor, to be operated in CW mode (1 MHz). MariX provides FEL emission in the range 0.2–8 keV with photons per pulse ideally suited for photoelectric effect and inelastic X-ray scattering experiments. The accelerator complex includes an early stage that supports an advanced inverse Compton source of very high-flux hard X-rays of energies up to 180 keV that is well adapted for large area radiological imaging, realizing a broad science programme and serving a multidisciplinary user community, covering fundamental science of matter and application to life sciences, including health at preclinical and clinical level.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/749999
Citazioni
ND
35
25
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.