Resistive Plate Chambers have largely been used in High Energy Physics and Cosmic Ray research. In view
of using this detector for calorimetry applications it is important to know the maximum measurable particle
density, or its intrinsic linearity limit, which is tightly related to the dimension of the discharge region. In this
paper we report the results of measurements performed at the Beam Test Facility (INFN National Laboratory
of Frascati, Italy) where the intrinsic linearity of bakelite RPCs operated in streamer mode has been tested at
different impinging particle densities.
Intrinsic linearity of bakelite Resistive Plate Chambers operated in streamer mode / Bartoli, B.; Bernardini, P.; Bi, X. J.; Branchini, P.; Budano, A.; Camarri, P.; Cao, Z.; Cardarelli, R.; Catalanotti, S.; Chen, S. Z.; Chen, T. L.; Creti, P.; Cui, S. W.; Dai, B. Z.; D’Amone, A.; Danzengluobu, Null; De Mitri, I.; D’Ettorre Piazzoli, B.; Di Girolamo, T.; Di Sciascio, G.; Feng, C. F.; Feng, Zhaoyang; Feng, Zhenyong; Gou, Q. B.; Guo, Y. Q.; He, H. H.; Hu, Haibing; Hu, Hongbo; Iacovacci, M.; Iuppa, R.; Jia, H. Y.; Labaciren, Null; Li, H. J.; Liguori, G.; Liu, C.; Liu, J.; Liu, M. Y.; Lu, H.; Ma, L. L.; Ma, X. H.; Mancarella, G.; Mari, S. M.; Marsella, G.; Martello, D.; Mastroianni, S.; Montini, P.; Ning, C. C.; Panareo, M.; Perrone, L.; Pistilli, P.; Ruggieri, F.; Salvini, P.; Santonico, R.; Shen, P. R.; Sheng, X. D.; Shi, F.; Surdo, A.; Tan, Y. H.; Vallania, P.; Vernetto, S.; Vigorito, C.; Wang, H.; Wu, C. Y.; Wu, H. R.; Xue, L.; Yang, Q. Y.; Yang, X. C.; Yao, Z. G.; Yuan, A. F.; Zha, M.; Zhang, H. M.; Zhang, L.; Zhang, X. Y.; Zhang, Y.; Zhao, J.; Zhaxiciren, Null; Zhaxisangzhu, Null; Zhou, X. X.; Zhu, F. R.; Zhu, Q. Q.; Zizzi, G.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 947:(2019), p. 162746. [10.1016/j.nima.2019.162746]
Intrinsic linearity of bakelite Resistive Plate Chambers operated in streamer mode
Bartoli, B.;Bernardini, P.;Bi, X. J.;Branchini, P.;Budano, A.;Camarri, P.;Cao, Z.;Cardarelli, R.;Catalanotti, S.;Chen, S. Z.;Chen, T. L.;Creti, P.;Cui, S. W.;Dai, B. Z.;D’Amone, A.;Danzengluobu, null;De Mitri, I.;D’Ettorre Piazzoli, B.;Di Girolamo, T.;Di Sciascio, G.;Feng, C. F.;Feng, Zhaoyang;Feng, Zhenyong;Gou, Q. B.;Guo, Y. Q.;He, H. H.;Hu, Haibing;Hu, Hongbo;Iacovacci, M.;Iuppa, R.;Jia, H. Y.;Labaciren, null;Li, H. J.;Liguori, G.;Liu, C.;Liu, J.;Liu, M. Y.;Lu, H.;Ma, L. L.;Ma, X. H.;Mancarella, G.;Mari, S. M.;Marsella, G.;Martello, D.;Mastroianni, S.;Montini, P.;Ning, C. C.;Panareo, M.;Perrone, L.;Pistilli, P.;Ruggieri, F.;Salvini, P.;Santonico, R.;Shen, P. R.;Sheng, X. D.;Shi, F.;Surdo, A.;Tan, Y. H.;Vallania, P.;Vernetto, S.;Vigorito, C.;Wang, H.;Wu, C. Y.;Wu, H. R.;Xue, L.;Yang, Q. Y.;Yang, X. C.;Yao, Z. G.;Yuan, A. F.;Zha, M.;Zhang, H. M.;Zhang, L.;Zhang, X. Y.;Zhang, Y.;Zhao, J.;Zhaxiciren, null;Zhaxisangzhu, null;Zhou, X. X.;Zhu, F. R.;Zhu, Q. Q.;Zizzi, G.
2019
Abstract
Resistive Plate Chambers have largely been used in High Energy Physics and Cosmic Ray research. In view
of using this detector for calorimetry applications it is important to know the maximum measurable particle
density, or its intrinsic linearity limit, which is tightly related to the dimension of the discharge region. In this
paper we report the results of measurements performed at the Beam Test Facility (INFN National Laboratory
of Frascati, Italy) where the intrinsic linearity of bakelite RPCs operated in streamer mode has been tested at
different impinging particle densities.
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.
Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/776687
Citazioni
ND
3
2
social impact
Conferma cancellazione
Sei sicuro che questo prodotto debba essere cancellato?
simulazione ASN
Il report seguente simula gli indicatori relativi alla propria produzione scientifica in relazione alle soglie ASN 2023-2025 del proprio SC/SSD. Si ricorda che il superamento dei valori soglia (almeno 2 su 3) è requisito necessario ma non sufficiente al conseguimento dell'abilitazione. La simulazione si basa sui dati IRIS e sugli indicatori bibliometrici alla data indicata e non tiene conto di eventuali periodi di congedo obbligatorio, che in sede di domanda ASN danno diritto a incrementi percentuali dei valori. La simulazione può differire dall'esito di un’eventuale domanda ASN sia per errori di catalogazione e/o dati mancanti in IRIS, sia per la variabilità dei dati bibliometrici nel tempo. Si consideri che Anvur calcola i valori degli indicatori all'ultima data utile per la presentazione delle domande.
La presente simulazione è stata realizzata sulla base delle specifiche raccolte sul tavolo ER del Focus Group IRIS coordinato dall’Università di Modena e Reggio Emilia e delle regole riportate nel DM 589/2018 e allegata Tabella A. Cineca, l’Università di Modena e Reggio Emilia e il Focus Group IRIS non si assumono alcuna responsabilità in merito all’uso che il diretto interessato o terzi faranno della simulazione. Si specifica inoltre che la simulazione contiene calcoli effettuati con dati e algoritmi di pubblico dominio e deve quindi essere considerata come un mero ausilio al calcolo svolgibile manualmente o con strumenti equivalenti.