BACKGROUND: Despite the well-known second trimester ultrasound signs, current possibilities of in utero surgical repair of open spina bifida require a timely detection of the spine defect. OBJECTIVE: To evaluate the diagnostic accuracy of the ratio between brain stem (BS) diameter and its distance to the occipital bone (BSOB) (BS/BSOB ratio) in the detection of fetuses with open spina bifida at first trimester ultrasound. METHODS: A systematic review and meta-analysis of diagnostic accuracy was performed by searching seven electronic databases from their inception to February 2019 for all studies assessing the association between BS/BSOB ratio and diagnosis of spine bifida. Diagnostic accuracy of BS/BSOB ratio in prenatal diagnosis of spine bifida was assessed as sensitivity, specificity, positive and negative likelihood ratios (LR + and LR-), and area under the curve (AUC) on SROC curves. RESULTS: Four studies, including 17,598 fetuses with 23 cases of open spina bifida, were included in the meta-analysis. BS/BSOB ratio showed pooled sensitivity of 0.70 (95% CI 0.47-0.87; I2 = 78.3%), specificity of 1.00 (95% CI 0.99-1.0; I2 = 99.2%), LR + and LR- of 51.44 (95% CI 9.53-277.64; I2 = 85.5%) and 0.23 (95% CI 0.04-1.17; I2 = 64.8%), respectively, and an AUC of 0.9649. CONCLUSION: First trimester BS/BSOB ratio has a high diagnostic accuracy in detecting fetuses with open spina bifida.

First trimester detection of fetal open spina bifida using BS/BSOB ratio / Sirico, A.; Raffone, A.; Lanzone, A.; Saccone, G.; Travaglino, A.; Sarno, L.; Rizzo, G.; Zullo, F.; Maruotti, G. M.. - In: ARCHIVES OF GYNECOLOGY AND OBSTETRICS. - ISSN 0932-0067. - (2020). [10.1007/s00404-019-05422-3]

First trimester detection of fetal open spina bifida using BS/BSOB ratio

Sirico A.;Raffone A.;Saccone G.;Travaglino A.;Sarno L.;Zullo F.;Maruotti G. M.
2020

Abstract

BACKGROUND: Despite the well-known second trimester ultrasound signs, current possibilities of in utero surgical repair of open spina bifida require a timely detection of the spine defect. OBJECTIVE: To evaluate the diagnostic accuracy of the ratio between brain stem (BS) diameter and its distance to the occipital bone (BSOB) (BS/BSOB ratio) in the detection of fetuses with open spina bifida at first trimester ultrasound. METHODS: A systematic review and meta-analysis of diagnostic accuracy was performed by searching seven electronic databases from their inception to February 2019 for all studies assessing the association between BS/BSOB ratio and diagnosis of spine bifida. Diagnostic accuracy of BS/BSOB ratio in prenatal diagnosis of spine bifida was assessed as sensitivity, specificity, positive and negative likelihood ratios (LR + and LR-), and area under the curve (AUC) on SROC curves. RESULTS: Four studies, including 17,598 fetuses with 23 cases of open spina bifida, were included in the meta-analysis. BS/BSOB ratio showed pooled sensitivity of 0.70 (95% CI 0.47-0.87; I2 = 78.3%), specificity of 1.00 (95% CI 0.99-1.0; I2 = 99.2%), LR + and LR- of 51.44 (95% CI 9.53-277.64; I2 = 85.5%) and 0.23 (95% CI 0.04-1.17; I2 = 64.8%), respectively, and an AUC of 0.9649. CONCLUSION: First trimester BS/BSOB ratio has a high diagnostic accuracy in detecting fetuses with open spina bifida.
2020
First trimester detection of fetal open spina bifida using BS/BSOB ratio / Sirico, A.; Raffone, A.; Lanzone, A.; Saccone, G.; Travaglino, A.; Sarno, L.; Rizzo, G.; Zullo, F.; Maruotti, G. M.. - In: ARCHIVES OF GYNECOLOGY AND OBSTETRICS. - ISSN 0932-0067. - (2020). [10.1007/s00404-019-05422-3]
File in questo prodotto:
File Dimensione Formato  
186 bs bsob spina bifida - Archives DOI - Sirico.pdf

accesso aperto

Descrizione: Articolo principale
Tipologia: Documento in Pre-print
Licenza: Dominio pubblico
Dimensione 1.68 MB
Formato Adobe PDF
1.68 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/782312
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 20
  • ???jsp.display-item.citation.isi??? 14
social impact