Muon radiography is a methodology which enables measuring the mass distribution within large objects. It exploits the abundant flux of cosmic muons and uses detectors with different technologies depending on the application. As the sensitive surface and geometric acceptance are two fundamental parameters for increasing the collection of muons, the optimization of the detectors is very significant. Here we show a potentially innovative detector of size and shape suitable to be inserted inside a borehole, that optimizes the sensitive area and maximizes the angular acceptance thanks to its cylindrical geometry obtained using plastic arc-shaped scintillators. Good spatial resolution is obtained with a reasonable number of channels. The dimensions of the detector make it ideal for use in 25 cm diameter wells. Detailed simulations based on Monte Carlo methods show great cavity detection capability. The detector has been tested in the laboratory, achieving overall excellent performance.

A new cylindrical borehole detector for radiographic imaging with muons / Cimmino, L.; Ambrosino, F.; Anastasio, A.; D'Errico, M.; Masone, V.; Roscilli, L.; Saracino, G.. - In: SCIENTIFIC REPORTS. - ISSN 2045-2322. - 11:1(2021), p. 17425. [10.1038/s41598-021-96247-1]

A new cylindrical borehole detector for radiographic imaging with muons

Cimmino L.
;
Ambrosino F.;Anastasio A.;D'Errico M.;Saracino G.
2021

Abstract

Muon radiography is a methodology which enables measuring the mass distribution within large objects. It exploits the abundant flux of cosmic muons and uses detectors with different technologies depending on the application. As the sensitive surface and geometric acceptance are two fundamental parameters for increasing the collection of muons, the optimization of the detectors is very significant. Here we show a potentially innovative detector of size and shape suitable to be inserted inside a borehole, that optimizes the sensitive area and maximizes the angular acceptance thanks to its cylindrical geometry obtained using plastic arc-shaped scintillators. Good spatial resolution is obtained with a reasonable number of channels. The dimensions of the detector make it ideal for use in 25 cm diameter wells. Detailed simulations based on Monte Carlo methods show great cavity detection capability. The detector has been tested in the laboratory, achieving overall excellent performance.
2021
A new cylindrical borehole detector for radiographic imaging with muons / Cimmino, L.; Ambrosino, F.; Anastasio, A.; D'Errico, M.; Masone, V.; Roscilli, L.; Saracino, G.. - In: SCIENTIFIC REPORTS. - ISSN 2045-2322. - 11:1(2021), p. 17425. [10.1038/s41598-021-96247-1]
File in questo prodotto:
File Dimensione Formato  
STRESS2021.pdf

accesso aperto

Tipologia: Versione Editoriale (PDF)
Licenza: Creative commons
Dimensione 2.46 MB
Formato Adobe PDF
2.46 MB Adobe PDF Visualizza/Apri

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/866296
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 9
social impact