The assessment of the left main coronary artery (LMCA) by coronary angiography has several limitations. The fractional flow reserve (FFR) is useful for the functional evaluation of LMCA stenoses. The instantaneous wave-free ratio (iFR), a resting index, was developed to simplify functional coronary assessment. However, its performance for LMCA stenoses has yet to be explored. The iFR was measured at rest, and the FFR was measured under maximal hyperemia. We calculated that a sample size of 90 lesions would have provided 90% power at a 5% significance level to detect an Area Under the Curve (AUC) < 0.7 for the iFR to identify FFR-positive stenoses. A total of 91 measurements were performed on angiographically intermediate LMCA stenoses at three centers. The comparison between the iFR and the FFR showed a significant correlation (r = 0.67, p < 0.001). At receiver operating characteristic (ROC) analysis, the iFR revealed a good diagnostic performance when compared to the FFR (AUC = 0.84; p < 0.001). A classification agreement between the iFR and the FFR was recorded in 81% of cases. The left ventricular ejection fraction (LVEF) was an independent predictor of the discrepancy between the FFR and iFR values (p = 0.040). The present study is the first demonstrating that the assessment of LMCA stenoses with the instantaneous wave-free ratio is a reliable adenosine-free alternative to classic fractional flow reserve. If confirmed in larger populations, these findings could be of relevance for real world daily practice.
Reliability of instantaneous wave-free ratio (iFR) for the evaluation of left main coronary artery lesions / De Rosa, S.; Polimeni, A.; De Velli, G.; Conte, M.; Sorrentino, S.; Spaccarotella, C.; Mongiardo, A.; Sabatino, J.; Contarini, M.; Todaro, D.; Indolfi, C.. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - 8:8(2019), p. 1143. [10.3390/jcm8081143]
Reliability of instantaneous wave-free ratio (iFR) for the evaluation of left main coronary artery lesions
Spaccarotella C.;Indolfi C.
2019
Abstract
The assessment of the left main coronary artery (LMCA) by coronary angiography has several limitations. The fractional flow reserve (FFR) is useful for the functional evaluation of LMCA stenoses. The instantaneous wave-free ratio (iFR), a resting index, was developed to simplify functional coronary assessment. However, its performance for LMCA stenoses has yet to be explored. The iFR was measured at rest, and the FFR was measured under maximal hyperemia. We calculated that a sample size of 90 lesions would have provided 90% power at a 5% significance level to detect an Area Under the Curve (AUC) < 0.7 for the iFR to identify FFR-positive stenoses. A total of 91 measurements were performed on angiographically intermediate LMCA stenoses at three centers. The comparison between the iFR and the FFR showed a significant correlation (r = 0.67, p < 0.001). At receiver operating characteristic (ROC) analysis, the iFR revealed a good diagnostic performance when compared to the FFR (AUC = 0.84; p < 0.001). A classification agreement between the iFR and the FFR was recorded in 81% of cases. The left ventricular ejection fraction (LVEF) was an independent predictor of the discrepancy between the FFR and iFR values (p = 0.040). The present study is the first demonstrating that the assessment of LMCA stenoses with the instantaneous wave-free ratio is a reliable adenosine-free alternative to classic fractional flow reserve. If confirmed in larger populations, these findings could be of relevance for real world daily practice.File | Dimensione | Formato | |
---|---|---|---|
Reliability of iFR_De Rosa_J Clin Med.pdf
accesso aperto
Tipologia:
Versione Editoriale (PDF)
Licenza:
Accesso privato/ristretto
Dimensione
1.44 MB
Formato
Adobe PDF
|
1.44 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.