Background: Prostate volume (PV) is a useful tool in risk stratification, diagnosis, and follow-up of numerous prostatic diseases including prostate cancer and benign prostatic hypertrophy. There is currently no accepted ideal PV measurement method. Objective: This study compares multiple means of PV estimation, including digital rectal examination (DRE), transrectal ultrasound (TRUS), and magnetic resonance imaging (MRI), and radical prostatectomy specimens to determine the best volume measurement style. Methods: A retrospective, observational, single-site study with patients identified using an institutional database was performed. A total of 197 patients who underwent robot-assisted radical prostatectomy were considered. Data collected included age, serum PSA at the time of the prostate biopsy, clinical T stage, Gleason score, and PVs for each of the following methods: DRE, TRUS, MRI, and surgical specimen weight (SPW) and volume. Results: A paired t test was performed, which reported a statistically significant difference between PV measures (DRE, TRUS, MRI ellipsoid, MRI bullet, SP ellipsoid, and SP bullet) and the actual prostate weight. Lowest differences were reported for SP ellipsoid volume (M = -2.37; standard deviation [SD] = 10.227; t[167] = -3.011; and p = 0.003), MRI ellipsoid volume (M = -4.318; SD = 9.53; t[167] = -5.87; and p = 0.000), and MRI bullet volume (M = 5.31; SD = 10.77; t[167] = 6.387; and p = 0.000). Conclusion: The PV obtained by MRI has proven to correlate with the PV obtained via auto-segmentation software as well as actual SPW, while also being more cost-effective and time-efficient. Therefore, demonstrating that MRI estimated the PV is an adequate method for use in clinical practice for therapeutic planning and patient follow-up.

The Comparison of Imaging and Clinical Methods to Estimate Prostate Volume: A Single-Centre Retrospective Study / Massanova, M.; Robertson, S.; Barone, B.; Dutto, L.; Caputo, V. F.; Bhatt, J. R.; Ahmad, I.; Bada, M.; Obeidallah, A.; Crocetto, F.. - In: UROLOGIA INTERNATIONALIS. - ISSN 0042-1138. - 105:9-10(2021), pp. 804-810. [10.1159/000516681]

The Comparison of Imaging and Clinical Methods to Estimate Prostate Volume: A Single-Centre Retrospective Study

Barone B.;Caputo V. F.;Crocetto F.
Ultimo
2021

Abstract

Background: Prostate volume (PV) is a useful tool in risk stratification, diagnosis, and follow-up of numerous prostatic diseases including prostate cancer and benign prostatic hypertrophy. There is currently no accepted ideal PV measurement method. Objective: This study compares multiple means of PV estimation, including digital rectal examination (DRE), transrectal ultrasound (TRUS), and magnetic resonance imaging (MRI), and radical prostatectomy specimens to determine the best volume measurement style. Methods: A retrospective, observational, single-site study with patients identified using an institutional database was performed. A total of 197 patients who underwent robot-assisted radical prostatectomy were considered. Data collected included age, serum PSA at the time of the prostate biopsy, clinical T stage, Gleason score, and PVs for each of the following methods: DRE, TRUS, MRI, and surgical specimen weight (SPW) and volume. Results: A paired t test was performed, which reported a statistically significant difference between PV measures (DRE, TRUS, MRI ellipsoid, MRI bullet, SP ellipsoid, and SP bullet) and the actual prostate weight. Lowest differences were reported for SP ellipsoid volume (M = -2.37; standard deviation [SD] = 10.227; t[167] = -3.011; and p = 0.003), MRI ellipsoid volume (M = -4.318; SD = 9.53; t[167] = -5.87; and p = 0.000), and MRI bullet volume (M = 5.31; SD = 10.77; t[167] = 6.387; and p = 0.000). Conclusion: The PV obtained by MRI has proven to correlate with the PV obtained via auto-segmentation software as well as actual SPW, while also being more cost-effective and time-efficient. Therefore, demonstrating that MRI estimated the PV is an adequate method for use in clinical practice for therapeutic planning and patient follow-up.
2021
The Comparison of Imaging and Clinical Methods to Estimate Prostate Volume: A Single-Centre Retrospective Study / Massanova, M.; Robertson, S.; Barone, B.; Dutto, L.; Caputo, V. F.; Bhatt, J. R.; Ahmad, I.; Bada, M.; Obeidallah, A.; Crocetto, F.. - In: UROLOGIA INTERNATIONALIS. - ISSN 0042-1138. - 105:9-10(2021), pp. 804-810. [10.1159/000516681]
File in questo prodotto:
File Dimensione Formato  
massanova2021.pdf

non disponibili

Tipologia: Versione Editoriale (PDF)
Licenza: Accesso privato/ristretto
Dimensione 379.4 kB
Formato Adobe PDF
379.4 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/882955
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 35
  • ???jsp.display-item.citation.isi??? 33
social impact