The paper is focused on the formalization of an experimental procedure aimed to char-acterize the efficiency behaviour of a Permanent Magnet Synchronous Motor-based drive. The characterization is intended to expose the analytical behaviour of the system efficiency by the actual operating condition assigned through torque/speed value. The availability of such a relation in a simple analytical form would allow for real-time adjustment by advanced power management strategies to maximize the whole system efficiency. The proposed method is based on a defined set of measures corresponding to several drive operating conditions. A straightforward elaboration procedure is then formulated with the aim to quantify the different parameters, which intervene in the efficiency characterization. The method has been applied on a 155 kW drive. The results show that good accuracy is achieved while keeping the analytical approach relatively simple.
Efficiency Analytical Characterization for Brushless Electric Drives / Brando, G.; Dannier, A.; Del Pizzo, A.. - In: ENERGIES. - ISSN 1996-1073. - 15:8(2022), p. 2963. [10.3390/en15082963]
Efficiency Analytical Characterization for Brushless Electric Drives
Brando G.;Dannier A.
;Del Pizzo A.
2022
Abstract
The paper is focused on the formalization of an experimental procedure aimed to char-acterize the efficiency behaviour of a Permanent Magnet Synchronous Motor-based drive. The characterization is intended to expose the analytical behaviour of the system efficiency by the actual operating condition assigned through torque/speed value. The availability of such a relation in a simple analytical form would allow for real-time adjustment by advanced power management strategies to maximize the whole system efficiency. The proposed method is based on a defined set of measures corresponding to several drive operating conditions. A straightforward elaboration procedure is then formulated with the aim to quantify the different parameters, which intervene in the efficiency characterization. The method has been applied on a 155 kW drive. The results show that good accuracy is achieved while keeping the analytical approach relatively simple.File | Dimensione | Formato | |
---|---|---|---|
energies-15-02963-v2.pdf
accesso aperto
Tipologia:
Documento in Post-print
Licenza:
Dominio pubblico
Dimensione
2.77 MB
Formato
Adobe PDF
|
2.77 MB | Adobe PDF | Visualizza/Apri |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.