Alzheimer’s Disease is the most common cause of dementia, whose progression spans in different stages, from very mild cognitive impairment to mild and severe conditions. In clinical trials, Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET) are mostly used for the early diagnosis of neurodegenerative disorders since they provide volumetric and metabolic function information of the brain, respectively. In recent years, Deep Learning (DL) has been employed in medical imaging with promising results. Moreover, the use of the deep neural networks, especially Convolutional Neural Networks (CNNs), has also enabled the development of DL-based solutions in domains characterized by the need of leveraging information coming from multiple data sources, raising the Multimodal Deep Learning (MDL). In this paper, we conduct a systematic analysis of MDL approaches for dementia severity assessment exploiting MRI and PET scans. We propose a Multi Input–Multi Output 3D CNN whose training iterations change according to the characteristic of the input as it is able to handle incomplete acquisitions, in which one image modality is missed. Experiments performed on OASIS-3 dataset show the satisfactory results of the implemented network, which outperforms approaches exploiting both single image modality and different MDL fusion techniques.

Multi input–Multi output 3D CNN for dementia severity assessment with incomplete multimodal data / Gravina, Michela; García-Pedrero, Angel; Gonzalo-Martín, Consuelo; Sansone, Carlo; Soda, Paolo. - In: ARTIFICIAL INTELLIGENCE IN MEDICINE. - ISSN 0933-3657. - 149:(2024), p. 102774. [10.1016/j.artmed.2024.102774]

Multi input–Multi output 3D CNN for dementia severity assessment with incomplete multimodal data

Gravina, Michela;Sansone, Carlo;
2024

Abstract

Alzheimer’s Disease is the most common cause of dementia, whose progression spans in different stages, from very mild cognitive impairment to mild and severe conditions. In clinical trials, Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET) are mostly used for the early diagnosis of neurodegenerative disorders since they provide volumetric and metabolic function information of the brain, respectively. In recent years, Deep Learning (DL) has been employed in medical imaging with promising results. Moreover, the use of the deep neural networks, especially Convolutional Neural Networks (CNNs), has also enabled the development of DL-based solutions in domains characterized by the need of leveraging information coming from multiple data sources, raising the Multimodal Deep Learning (MDL). In this paper, we conduct a systematic analysis of MDL approaches for dementia severity assessment exploiting MRI and PET scans. We propose a Multi Input–Multi Output 3D CNN whose training iterations change according to the characteristic of the input as it is able to handle incomplete acquisitions, in which one image modality is missed. Experiments performed on OASIS-3 dataset show the satisfactory results of the implemented network, which outperforms approaches exploiting both single image modality and different MDL fusion techniques.
2024
Multi input–Multi output 3D CNN for dementia severity assessment with incomplete multimodal data / Gravina, Michela; García-Pedrero, Angel; Gonzalo-Martín, Consuelo; Sansone, Carlo; Soda, Paolo. - In: ARTIFICIAL INTELLIGENCE IN MEDICINE. - ISSN 0933-3657. - 149:(2024), p. 102774. [10.1016/j.artmed.2024.102774]
File in questo prodotto:
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/952331
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 1
social impact