Purpose: To describe the good outcome of implantable collamer lens (ICL) rotation to reduce post-operative vault. Methods: Retrospective analysis of case report. A 43-year-old woman had V4c EVO + myopic non-toric ICL implantation and post-operatively she presented with anisocoria and high vault. She underwent surgery to rotate the ICL 90 degrees to a vertical orientation. Results: We achieved a reduction in the vault from 1020 to 486 μm after vertical ICL rotation. Satisfactory refractive outcome and optimal vault were achieved and maintained during the period of follow-up. Conclusion: Optimal ICL sizing is important as too high vault/clearance is associated with problems such as angle closure glaucoma, pupil dilatation and anisocoria and too low vault/clearance to increased risk of cataract formation. Non-toric ICL rotation can be a simple surgical technique to deal with oversized lenses thus avoiding ICL exchange.

Vertical implantable collamer lens (ICL) rotation for the management of high vault due to lens oversizing / Matarazzo, F.; Day, A. C.; Fernandez-Vega Cueto, L.; Maurino, V.. - In: INTERNATIONAL OPHTHALMOLOGY. - ISSN 0165-5701. - 38:6(2018), pp. 2689-2692. [10.1007/s10792-017-0757-2]

Vertical implantable collamer lens (ICL) rotation for the management of high vault due to lens oversizing

Matarazzo F.
Primo
;
2018

Abstract

Purpose: To describe the good outcome of implantable collamer lens (ICL) rotation to reduce post-operative vault. Methods: Retrospective analysis of case report. A 43-year-old woman had V4c EVO + myopic non-toric ICL implantation and post-operatively she presented with anisocoria and high vault. She underwent surgery to rotate the ICL 90 degrees to a vertical orientation. Results: We achieved a reduction in the vault from 1020 to 486 μm after vertical ICL rotation. Satisfactory refractive outcome and optimal vault were achieved and maintained during the period of follow-up. Conclusion: Optimal ICL sizing is important as too high vault/clearance is associated with problems such as angle closure glaucoma, pupil dilatation and anisocoria and too low vault/clearance to increased risk of cataract formation. Non-toric ICL rotation can be a simple surgical technique to deal with oversized lenses thus avoiding ICL exchange.
2018
Vertical implantable collamer lens (ICL) rotation for the management of high vault due to lens oversizing / Matarazzo, F.; Day, A. C.; Fernandez-Vega Cueto, L.; Maurino, V.. - In: INTERNATIONAL OPHTHALMOLOGY. - ISSN 0165-5701. - 38:6(2018), pp. 2689-2692. [10.1007/s10792-017-0757-2]
File in questo prodotto:
File Dimensione Formato  
Vertical implantable collamer lens (ICL) rotation.pdf

solo utenti autorizzati

Tipologia: Versione Editoriale (PDF)
Licenza: Copyright dell'editore
Dimensione 820.28 kB
Formato Adobe PDF
820.28 kB Adobe PDF   Visualizza/Apri   Richiedi una copia

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11588/959365
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 45
  • ???jsp.display-item.citation.isi??? 33
social impact