Purpose: To describe the good outcome of implantable collamer lens (ICL) rotation to reduce post-operative vault. Methods: Retrospective analysis of case report. A 43-year-old woman had V4c EVO + myopic non-toric ICL implantation and post-operatively she presented with anisocoria and high vault. She underwent surgery to rotate the ICL 90 degrees to a vertical orientation. Results: We achieved a reduction in the vault from 1020 to 486 μm after vertical ICL rotation. Satisfactory refractive outcome and optimal vault were achieved and maintained during the period of follow-up. Conclusion: Optimal ICL sizing is important as too high vault/clearance is associated with problems such as angle closure glaucoma, pupil dilatation and anisocoria and too low vault/clearance to increased risk of cataract formation. Non-toric ICL rotation can be a simple surgical technique to deal with oversized lenses thus avoiding ICL exchange.
Vertical implantable collamer lens (ICL) rotation for the management of high vault due to lens oversizing / Matarazzo, F.; Day, A. C.; Fernandez-Vega Cueto, L.; Maurino, V.. - In: INTERNATIONAL OPHTHALMOLOGY. - ISSN 0165-5701. - 38:6(2018), pp. 2689-2692. [10.1007/s10792-017-0757-2]
Vertical implantable collamer lens (ICL) rotation for the management of high vault due to lens oversizing
Matarazzo F.Primo
;
2018
Abstract
Purpose: To describe the good outcome of implantable collamer lens (ICL) rotation to reduce post-operative vault. Methods: Retrospective analysis of case report. A 43-year-old woman had V4c EVO + myopic non-toric ICL implantation and post-operatively she presented with anisocoria and high vault. She underwent surgery to rotate the ICL 90 degrees to a vertical orientation. Results: We achieved a reduction in the vault from 1020 to 486 μm after vertical ICL rotation. Satisfactory refractive outcome and optimal vault were achieved and maintained during the period of follow-up. Conclusion: Optimal ICL sizing is important as too high vault/clearance is associated with problems such as angle closure glaucoma, pupil dilatation and anisocoria and too low vault/clearance to increased risk of cataract formation. Non-toric ICL rotation can be a simple surgical technique to deal with oversized lenses thus avoiding ICL exchange.File | Dimensione | Formato | |
---|---|---|---|
Vertical implantable collamer lens (ICL) rotation.pdf
solo utenti autorizzati
Tipologia:
Versione Editoriale (PDF)
Licenza:
Copyright dell'editore
Dimensione
820.28 kB
Formato
Adobe PDF
|
820.28 kB | Adobe PDF | Visualizza/Apri Richiedi una copia |
I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.